Device
Address
D8750
Slave Number (Port 25)
D8751
Slave Number (Port 26)
D8752
Slave Number (Port 27)
D8753
Slave Number (Port 28)
D8754
Slave Number (Port 29)
D8755
Slave Number (Port 30)
D8756
Slave Number (Port 31)
D8757
Slave Number (Port 32)
D8758
Slave Number (Port 33)
D8759
EMAIL Instruction Detailed Error Information (Ethernet Port 1)
D8760
Communication Mode Information
(Client Connection)
D8761
D8762 to
— Reserved —
D8773
D8774
Remote Host Number of Connection 9 (1 to 255)
D8775
Remote Host Number of Connection 10 (1 to 255)
D8776
Remote Host Number of Connection 11 (1 to 255)
D8777
Remote Host Number of Connection 12 (1 to 255)
D8778
Remote Host Number of Connection 13 (1 to 255)
D8779
Remote Host Number of Connection 14 (1 to 255)
D8780
Remote Host Number of Connection 15 (1 to 255)
D8781
Remote Host Number of Connection 16 (1 to 255)
D8782
BACnet Operation Status
D8783
BACnet Error Information
D8784 to
— Reserved —
D8899
Supplementary Descriptions of the Special Data Registers
■ D8000: Quantity of Inputs
The number of FC6A Series MICROSmart inputs is written to this register.
The total number of inputs for the CPU module and the expansion modules is written to this register.
■ D8001: Quantity of Outputs
The number of FC6A Series MICROSmart outputs is written to this register.
The total number of outputs for the CPU module and the expansion modules is written to this register.
■ D8002: CPU Module Type Information
CPU module type information is written this register.
0 (00h): 16-I/O type
1 (01h): 24-I/O type
2 (02h): 40-I/O type (All-in-One CPU module)
18 (12h): 40-I/O type (CAN J1939 All-in-One CPU module)
32 (20h): Plus 16-I/O type
33 (21h): Plus 32-I/O type
■ D8005: General Error Code
FC6A Series MICROSmart general error information is written to this register. When a general error occurs, the bit corresponding
to the error occurred turns on. The general error and user program execution error can be cleared by writing "1" to the most
significant bit of D8005. For details on general error codes, see Chapter 13 "General Error Codes" in the "FC6A Series
MICROSmart User's Manual".
■ D8006: User Program Execution Error Code
FC6A Series MICROSmartuser program execution error information is written to this register. When a user program execution
error occurs, the error code corresponding to the error that occurred is written to this register. For details on user program
execution errors, see "User Program Execution Error" on page A-12.
■ D8008 to D8021: Calendar/Clock Data
D8008 through D8021 are used for reading calendar/clock data from the internal clock and for writing calendar/clock data to the
internal clock. For details on the calendar/clock data, see Chapter 5 "Clock Function" in the "FC6A Series MICROSmart User's Manual".
2-28
Description
Connection 9 to 12
Connection 13 to 16
FC6A S
MICROS
L
ERIES
MART
P
M
ADDER
ROGRAMMING
ANUAL
Update Timing
FC9Y-B1726
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents