11: W
P
EEK
ROGRAMMER
3. S2 (source 2): Initialization Input
This setting specifies the device to initialize the days of the week and the times stored in the data register region that starts
from S1 (source 1).
The values configured on the parameter tabs are stored in the data registers by turning on the initialization input.
This setting is only used when indirectly specifying the settings for the WEEK instruction with data registers.
4. S3 (source 3): The number of parameter tabs
This setting configures the number of parameter tabs.
This setting is shared in common with "To configure the day of the week and the time as fixed settings". See "4. S3 (source
3): Number of parameter tabs" on page 11-4.
5. D1 (destination 1): Output
This setting configures the output for the results when the configured day of the week and time and the current day of the
week and time are compared.
This setting is shared in common with "To configure the day of the week and the time as fixed settings". See "5. D1
(destination 1): Output" on page 11-5.
6. Pulse Output
This setting configures the operation for D1 (output). This setting is applied to all parameter tabs and is shared in common
with "To configure the day of the week and the time as fixed settings". See "6. Pulse Output" on page 11-5.
7. Data Register Allocation
Click this button to display the Device Allocation dialog box. As shown below, a table showing the data registers and their
corresponding WEEK instruction settings is displayed on the dialog box (8). Click Allocate Comments (9) and you can
configure the comments for the data registers that correspond to the names of the settings.
This button is only used when indirectly specifying the settings for the WEEK instruction with data registers.
• Device Allocation dialog box
9.
• Parameter tab
This tab configures the ON/OFF settings for the output. A maximum of 20 parameter tabs can be configured for 1 WEEK
instruction.
If indirectly specifying the settings for the WEEK instruction with data registers, the settings configured on the parameter tabs are
stored in the data registers when the initialization input is turned on.
This setting is shared in common with "To configure the day of the week and the time as fixed settings". See "Parameter tab" on
page 11-5.
• Preview
The preview shows the ON/OFF state for the output based on the settings configured on the parameter tabs as a time chart.
This function is shared in common with "To configure the day of the week and the time as fixed settings". See "Preview" on page
11-6.