18: P
O
I
ULSE
UTPUT
NSTRUCTIONS
5. D1 (destination 1): Monitor Register
D1 specifies the first data register of the data registers to use with ARAMP1, ARAMP2, ARAMP3 or ARAMP4. Starting from the
specified data register, 11 consecutive data registers are used. Specify the first data register so that the device range is not
exceeded. The contents of the monitor registers are read-only.
Address
Starting number+0
Starting number+1
Starting number+2
Starting number+3
Starting number+4
Starting number+5
Starting number+6
Starting number+7
Starting number+8
Starting number+9
Starting number+10
*1 The upper and lower data registers change according to the 32-bit data storage method specified.
For details, see "32-bit Data Storage" on page 3-9.
Next step number
This register stores the number of the step to execute next.
If the next step is 0, pulse output ends after the currently executed step is complete.
Running step number
This register stores the number of the step that is currently being executed.
Steady pulse frequency monitor
This register stores the steady pulse frequency for the step that is currently being executed.
Frequency change time monitor
This register stores the frequency change time for the step that is currently being executed.
Set the time between 10 and 10,000 ms in increments of 1 ms. The first digit of the setting is handled as zero. For example,
if 144 is entered, the set value is handled as 140 ms.
Preset value monitor
This register stores the number of pulses to output for the running step.
Current value
This register stores the number of pulses that have been output for the step that is currently being executed. The current
value is updated when the ARAMP instruction is executed at each scan.
18-50
Function
Next step number
Running step number
Steady pulse frequency
*1
monitor (high word)
Frequency change time
*1
monitor (low word)
Reserved
Frequency change time
monitor
Preset value monitor
*1
(high word)
Preset value monitor
*1
(low word)
*1
Current value (high word)
*1
Current value (low word)
Error status
FC6A S
MICROS
ERIES
MART
Setting
CAN J1939 All-in-
All-in-One CPU
One CPU Module/
Module
Plus CPU Module
0 to 18
1 to 18
ARAMP1, ARAMP2:
15 to 100,000
ARAMP1 to ARAMP4:
(increments of 1 Hz)
15 to 100,000
ARAMP3, ARAMP4:
(increments of 1 Hz)
15 to 5,000
(increments of 1 Hz)
10 to 10,000 (increments of 1 ms)
The first digit of the setting is handled as zero.
1 to 100,000,000 pulses
1 to 100,000,000 pulses
0 to 9
L
P
M
ADDER
ROGRAMMING
ANUAL
Reference
"Next step number" on
page 18-50
"Running step number" on
page 18-50
"Steady pulse frequency
monitor" on page 18-50
"Frequency change time
monitor" on page 18-50
"Preset value monitor" on
page 18-50
"Current value" on page
18-50
"Error status" on page 18-
51