Troubleshooting When No Error Is Displayed; General Troubleshooting - MUTOH Kona 760 Service Manual

For machine versions: a1, a2, a3 and a4
Hide thumbs Also See for Kona 760:
Table of Contents

Advertisement

Service manual Kona cutting plotter
Troubleshooting
6.1

Troubleshooting when no error is displayed

6.1.1

General troubleshooting

Power switch is turned on but the cutting plotter does not operate:
Connect power cable.
1
Check wall outlet.
2
Check if LED LD1G on the mainboard is lit green.
3
Media is present but does not start loading:
Lower the pressure roller lever
1
Clean the media sensors.
2
Check media sensors and lever sensor in diagnostics mode.
3
Check X-motor connection.
4
122
Possible solution
Possible solution
Link
-
-
Mainboard > LED summary on page 73
Link
-
-
Menu overview > Sensors on page 116
X-motor and drive belt on page 33
J7 (X-motor and encoder) on page 72
AP-74380 - Revision 1.1