Troubleshooting
Error
Message
6261
No valid frame found
6262
No valid frame found
6263
No valid frame found
6264
No valid frame found
6265
No valid frame found
6266
No valid frame found
6267
No valid frame found
6268
No valid frame found
6269
No valid frame found
6271
Media shift detected
137
Description
No valid frame found during fast scan routine (after several
retries). Make sure all frame specifications are applied.
Only 1 frame point found during diagonal scan.
No frame points found during diagonal scan.
Thickness of left side of frame invalid
Varying thickness
Invalid thickness
Invalid frame angle
Requested X movement for fast scan cannot be executed.
Invalid spot type
Media displacement detected during cutting. Centre
markers of previous segment are shift more than 2mm.
Solution
To check:
Frame isn't found within 120 cm.
Media
space
before
frame
bottom is too much.
Frame bottom doesn't have the
correct specifications (minimum
thickness of 3mm on ALL sides,
thickness too varying, frame
height < 20cm, frame width <
10cm, frame angle < 5°)
To check:
Grits on media?
Pinches and grits clean?