Service manual Kona cutting plotter
Adjustments and calibrations
4.4.2

XY-distance accuracy test

The XY - Distance Accuracy tests are developed to check the actual X-Y cutting distance with
the sent vector data.
Please follow the procedure below to make the test:
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8:
Step 9:
Step 10:
102
Launch Mutoh's CUTserver.
Be sure that the cutter is connected with the Mutoh CUTserver.
Select which test to perform.
Select the appropriate COM-port and double-click.
Load a roll or sheet with at least the measurements indicated in the dropdown
menu.
Load a knife.
A box will be cut.
Peel out the box.
Measure the X length and Y width and enter them. Be sure to enter the values in
mm!
If the correct values have been entered, the following message will appear and the
test will be done.
m
AP-74380 - Revision 1.1