Jog Operation Example - Mitsubishi Electric MELSEC-QD75MH1 User Manual

Positioning module
Table of Contents

Advertisement

11 MANUAL CONTROL

11.2.5 JOG operation example

PLC READY signal
All axis servo ON
QD75 READY signal
Forward run JOG start signal
[Y8, YA, YC, YE]
Axis stop signal
[Y4, Y5, Y6, Y7]
BUSY signal[XC, XD, XE, XF] OFF
Fig. 11.7 Operation when the stop signal is turned ON during JOG operation
When the "stop signal" is turned ON during JOG operation
When the "stop signal" is turned ON during JOG operation, the JOG operation will
stop by the "deceleration stop" method.
JOG start signals will be ignored while the stop signal is ON.
The operation can be started by turning the stop signal OFF, and turning the JOG
start signal from OFF to ON again.
ON
[Y0]
OFF
ON
[Y1]
OFF
ON
[X0]
OFF
ON
OFF
OFF
ON
POINT
The QD75MH will not receive a "JOG start signal" while the "stop signal" is ON.
ON
11 - 13
MELSEC-Q
A JOG start signal OFF
ON
while the stop signal is ON will be ignored.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-q seriesMelsec-qd75mh2Melsec-qd75mh4

Table of Contents