Parameters
Characters
Integral Time (Cooling)
c-i
Derivative Time
c-d
(Cooling)
Dead Band
c-db
Manual Reset Value
of-r
Hysteresis (Heating)
hys
Hysteresis (Cooling)
chys
soak
000
Soak Time
wt-b
000
Wait Band
mv-s
000
MV at Stop
mv-e
000
MV at PV Error
SP Ramp Set Value
sprt
SP Ramp Fall Value
sprl
000
MV Upper Limit
ol-h
MV Lower Limit
ol-l
MV Change Rate Limit
orl
000
Position Proportional
db
Dead Band
Open/Close Hysteresis
oc-h
Extraction of Square
sqrp
Root Low-cut Point
000
Work Bit * ON Delay
to
w1
000
Work Bit * OFF Delay
to
w1
000
Communications
plcm
Monitor
*1
This setting is not displayed for heating and cooling control or for floating position-proportional control.
*2
Seconds is supported only by the E5DC, E5DC-B, and E5GC. (The E5DC must be manufactured in July 2014 or later
(version 2.2 or higher).)
E5@C Digital Temperature Controllers User's Manual (H174)
Setting (monitor) value
Integral/Derivative Time Unit of 1 s: 0 to 9,999
Integral/Derivative Time Unit of 0.1 s: 0.0 to 999.9
Integral/Derivative Time Unit of 1 s: 0 to 9,999
Integral/Derivative Time Unit of 0.1 s: 0.0 to 999.9
Temperature input: −199.9 to 999.9
Analog input: −19.99 to 99.99
0.0 to 100.0
Temperature input: 0.1 to 999.9
Analog input: 0.01 to 99.99
Temperature input: 0.1 to 999.9
Analog input: 0.01 to 99.99
1 to 9999
Temperature input: OFF or 0.1 to 999.9
Analog input: OFF, 0.01 to 99.99
Standard: −5.0 to 105.0
Heating/cooling: −105.0 to 105.0
Floating position-proportional control or the Direct
Setting of Position-proportional MV parameter set
to OFF: CLOS, HOLD, or OPEN
Close position-proportional control with the Direct
Setting of Position-proportional MV parameter set
to ON: −5.0 to 105.0
Same as the MV at Stop parameter.
OFF, 1 to 9,999
SAME, OFF, or 1 to 9,999
Standard control: MV lower limit + 0.1 to 105.0
Heating/cooling control: 0.0 to 105.0
Close position-proportional control: MV lower limit
+ 0.1 to 105.0
Standard control: −5.0 to MV upper limit − 0.1
Heating/cooling control: −105.0 to 0.0
Close position-proportional control: −5.0 to MV
upper limit −0.1
0.0 to 100.0
(0.0: MV Change Rate Limit Disabled)
Close position-proportional control: 0.1 to 10.0
Floating position-proportional control: 0.1 to 10.0
0.1 to 20.0
0.0 to 100.0
0 to 999
8on
0 to 999
8of
0 to 9999
A Appendices
Display
Default
233
Seconds
233.0
40
Seconds
40.0
0.0
°C or °F
0.00
%FS
50.0
%
°C or °F
1.0
0.10
%FS
1.0
°C or °F
0.10
%FS
1
min, h, or s
OFF
°C or °F
,
to
off
0.1
999.9
OFF
%FS
,
to
off
0.01
99.99
0.0
%
,
,
HOLD
None
clos
hold
open
0.0
%
0.0
%
OFF
EU/s,
,
to
off
1
EU/min,
9999
EU/h
SAME
EU/s,
,
,
same
off
EU/min,
to
1
9999
EU/h
100.0
%
0.0
%
−100.0
0.0
0.0
%/s
4.0
%
2.0
0.8
%
0.0
%
0
Seconds
0
Seconds
ms
Unit
*2
A
A - 27