Sign In
Upload
Manuals
Brands
Omron Manuals
Temperature Controller
E5DC
Omron E5DC Manuals
Manuals and User Guides for Omron E5DC. We have
10
Omron E5DC manuals available for free PDF download: User Manual, Communications Manual, Manual, Instruction Manual
Omron E5DC User Manual (440 pages)
Digital Temperature Controllers
Brand:
Omron
| Category:
Controller
| Size: 16 MB
Table of Contents
Preface
3
Terms and Conditions Agreement
4
Application Considerations
5
Disclaimers
5
Safety Precautions
6
Definition of Precautionary Information
6
Symbols
6
Precautions for Safe Use
9
Installation Precautions
12
Precautions for Operation
13
Shipping Standards
13
Preparations for Use
14
Versions
15
Revision History
16
Conventions Used in this Manual
17
Model Notation
17
Meanings of Abbreviations
17
How to Read Display Symbols
18
How this Manual Is Organized
18
Related Manuals
18
Sections in this Manual
19
Table of Contents
20
Introduction
25
Appearance, Features, and Functions of the E5@C
26
Appearance
26
Features
26
Main Functions
27
I/O Configuration and Model Number Legend
29
I/O Configuration
29
Model Number Legends
30
Preparations
39
Installation
40
Dimensions (Unit: MM)
40
Panel Cutout (Unit: MM)
44
Mounting
47
Using the Terminals
62
E5CC Terminal Block Wiring Example
62
E5CC-U Terminal Block Wiring Example
67
E5CC-B Terminal Block Wiring Example
70
E5EC/E5AC Terminal Block Wiring Example
74
E5EC-B Terminal Block Wiring Example
79
E5DC Terminal Block Wiring Example
84
E5DC-B Terminal Block Wiring Example
87
E5GC Terminal Block Wiring Example
90
Precautions When Wiring
93
Wiring
99
Insulation Block Diagrams
111
Using the Setup Tool Port
114
Procedure
114
Connection Method
114
Installing the Driver
121
Basic Application Flow
124
Power on
125
Part Names, Part Functions, and Setting Levels
126
Part Names and Functions
126
Entering Numeric Values
131
Setting Levels
132
Procedures after Turning on the Power Supply
135
Basic Flow of Operations
135
Basic Procedure
135
Basic Operation
143
Moving between Setting Levels
145
Moving to the Initial Setting Level
145
Moving to the Adjustment Level
146
Moving to the Protect Level
146
Moving to the Advanced Function Setting Level
147
Moving to the Communications Setting Level
149
Initial Setting Examples
150
Setting the Input Type
153
Input Type
153
Selecting the Temperature Unit
155
Temperature Unit
155
Selecting PID Control or ON/OFF Control (Not Supported for Position-Proportional Models.)
156
Setting Output Specifications
157
Control Periods (Not Supported for Position-Proportional Models.)
157
Direct and Reverse Operation
157
Assigned Output Functions (Assigning Control Outputs Is Not Supported for Position-Proportional Models.)
158
Auxiliary Output Opening or Closing in Alarm
161
Setting the Set Point (SP)
162
Changing the SP
162
Using ON/OFF Control (Not Supported for Position-Proportional Models.)
163
ON/OFF Control
163
Hysteresis
163
Settings
164
Determining PID Constants(AT, ST, Manual Setup)
166
Determining PID Constants (AT, ST, Manual Setup)
166
AT (Auto-Tuning)
166
ST (Self-Tuning) (Not Supported for Position-Proportional Models.)
169
RT (Robust Tuning) (Used for at or ST.)
170
Manual Setup
172
Alarm Outputs
174
Alarm Types
174
Alarm Values
177
Alarm Hysteresis
180
Standby Sequence
180
Alarm Latch
181
Using Heater Burnout (HB) and Heater Short (HS) Alarms (Not Supported for Position-Proportional Models.)
182
HB Alarm
182
HS Alarm
184
Installing Current Transformers (CT)
186
Calculating Detection Current Values
188
Application Examples
188
Customizing the PV/SP Display
192
PV/SP Display Selections
192
Advanced Operations
195
Shifting Input Values
197
Setting Scaling Upper and Lower Limits for Analog Inputs
199
Executing Heating/Cooling Control (Not Supported for Position-Proportional Models.)
201
Heating/Cooling Control
201
Using Event Inputs
205
Event Input Settings
205
How to Use the Multi-SP Function
205
Operation Commands Other than Multi-SP
206
Setting the SP Upper and Lower Limit Values
209
Set Point Limiter
209
Setting
210
Using the SP Ramp Function to Limit the SP Change Rate
211
SP Ramp
211
Using the Key Protect Level
213
Protection
213
Entering the Password to Move to the Protect Level
214
Displaying Only Parameters that Have Been Changed
216
Displaying Changed Parameters
216
OR Output of Alarms
218
Integrated Alarm
218
Alarm Delays
220
Loop Burnout Alarm (Not Supported for Position-Proportional Models.)
222
Loop Burnout Alarm (LBA)
222
Performing Manual Control
226
Manual MV
226
Using the Transfer Output for the Process Value, Set Point, or Other Data
230
Transfer Output Function
230
Simple Transfer Output Function
233
Using the Simple Program Function
236
Simple Program Function
236
Operation at the Program End
239
Application Example Using a Simple Program
241
Output Adjustment Functions
242
Output Limits
242
MV at Stop
242
MV at PV Error
243
Using the Extraction of Square Root Parameter
245
Extraction of Square Roots
245
Setting the Width of MV Variation
247
MV Change Rate Limit
247
Setting the PF Key
249
PF Setting (Function Key)
249
Displaying PV/SV Status
252
PV and SV Status Display Functions
252
Using a Remote SP
254
Controlling Valves (Can be Used with a Position-Proportional Model)
256
Logic Operations
259
The Logic Operation Function (CX-Thermo)
259
Using Logic Operations
259
Using Status Display Messages
267
Initializing Settings
269
Parameters
269
Conventions Used in this Section
272
Protect Level
273
Operation Level
277
Adjustment Level
288
Monitor/Setting Item Level
308
Manual Control Level
309
Initial Setting Level
311
Advanced Function Setting Level
331
Communications Setting Level
366
User Calibration
369
7-1 User Calibration
371
Parameter Structure
371
Thermocouple Calibration
372
Resistance Thermometer Calibration
375
Calibrating Analog Input
377
Calibrating the Transfer Output
381
Checking Indication Accuracy
383
Appendices
387
Specifications
387
A-1-1 Ratings
387
A-1-2 Characteristics
387
A-1-3 Rating and Characteristics of Options
387
A-1-4 Waterproof Packing
392
Unit Labels
392
A-1-6 Setup Tool Port Cover for Front Panel
393
A-1-7 Connector Cover of the Terminal Unit (Models with Push-In Plus Terminal Blocks
394
Current Transformer (CT
396
A-2-1 Specifications
396
A-2-2 Dimensions (Unit: MM
396
USB-Serial Conversion Cable and Conversion Cable
399
A-3-1 E58-CIFQ2 USB-Serial Conversion Cable
399
A-3-2 E58-CIFQ2-E Conversion Cable
400
Error Displays
401
A-5 Troubleshooting
405
A-5-1 Frequently Asked Questions
405
A-5-2 Checking Problems
408
Parameter Operation Lists
411
A-6-1 Operation Level
411
A-6-2 Adjustment Level
412
A-6-3 Initial Setting Level
414
A-6-4 Manual Control Level
418
A-6-5 Monitor/Setting Item Level
418
A-6-6 Advanced Function Setting Level
418
A-6-7 Protect Level
424
A-6-8 Communications Setting Level
424
A-6-9 Initialization According to Parameter Changes
425
Sensor Input Setting Range, Indication Range, Control Range
429
Setting Levels Diagram
430
Parameter Flow
431
Advertisement
Omron E5DC User Manual (416 pages)
Digital Temperature Controllers
Brand:
Omron
| Category:
Controller
| Size: 21 MB
Table of Contents
Preface
3
Terms and Conditions Agreement
4
Application Considerations
5
Disclaimers
5
Safety Precautions
6
Definition of Precautionary Information
6
Symbols
6
Precautions for Safe Use
9
Installation Precautions
12
Precautions for Operation
13
Shipping Standards
13
Preparations for Use
14
Versions
15
Revision History
16
Conventions Used in this Manual
17
Model Notation
17
Meanings of Abbreviations
17
How to Read Display Symbols
18
How this Manual Is Organized
18
Related Manuals
18
Sections in this Manual
19
Table of Contents
20
Introduction
25
Appearance, Features, and Functions of the E5@C
26
Appearance
26
Features
26
Main Functions
27
I/O Configuration and Model Number Legend
29
I/O Configuration
29
Model Number Legends
30
Preparations
37
Installation
38
Dimensions (Unit: MM)
38
Panel Cutout (Unit: MM)
42
Mounting
45
Using the Terminals
53
E5CC Terminal Block Wiring Example
53
E5CC-U Terminal Block Wiring Example
58
E5CC-B Terminal Block Wiring Example
61
E5EC/E5AC Terminal Block Wiring Example
65
E5EC-B Terminal Block Wiring Example
70
E5DC Terminal Block Wiring Example
74
E5GC Terminal Block Wiring Example
77
Precautions When Wiring
80
Wiring
85
Insulation Block Diagrams
96
Using the Setup Tool Port
99
Procedure
99
Connection Method
99
Installing the Driver
106
Basic Application Flow
108
Power on
109
Part Names, Part Functions, and Setting Levels
110
Part Names and Functions
110
Entering Numeric Values
115
Setting Levels
116
Procedures after Turning on the Power Supply
119
Basic Flow of Operations
119
Basic Procedure
119
Basic Operation
127
Moving between Setting Levels
129
Moving to the Initial Setting Level
129
Moving to the Adjustment Level
130
Moving to the Protect Level
130
Moving to the Advanced Function Setting Level
131
Moving to the Communications Setting Level
133
Initial Setting Examples
134
Setting the Input Type
137
Input Type
137
Selecting the Temperature Unit
139
Temperature Unit
139
Selecting PID Control or ON/OFF Control (Not Supported for Position-Proportional Models.)
140
Setting Output Specifications
141
Control Periods (Not Supported for Position-Proportional Models.)
141
Direct and Reverse Operation
141
Assigned Output Functions (Assigning Control Outputs Is Not Supported for Position-Proportional Models.)
142
Auxiliary Output Opening or Closing in Alarm
145
Setting the Set Point (SP)
146
Changing the SP
146
Using ON/OFF Control (Not Supported for Position-Proportional Models.)
147
ON/OFF Control
147
Settings
148
Determining PID Constants (AT, ST, Manual Setup)
150
AT (Auto-Tuning)
150
ST (Self-Tuning) (Not Supported for Position-Proportional Models.)
152
RT (Robust Tuning) (Used for at or ST.)
153
Manual Setup
155
Alarm Outputs
157
Alarm Types
157
Alarm Values
160
Alarm Hysteresis
163
Standby Sequence
163
Alarm Latch
164
Using Heater Burnout (HB) and Heater Short (HS) Alarms (Not Supported for Position-Proportional Models.)
165
HB Alarm
165
HS Alarm
167
Installing Current Transformers (CT)
169
Calculating Detection Current Values
171
Application Examples
171
Customizing the PV/SP Display
175
PV/SP Display Selections
175
Advanced Operations
177
Shifting Input Values
179
Setting Scaling Upper and Lower Limits for Analog Inputs
181
Executing Heating/Cooling Control (Not Supported for Position-Proportional Models.)
183
Heating/Cooling Control
183
Using Event Inputs
187
Event Input Settings
187
How to Use the Multi-SP Function
187
Operation Commands Other than Multi-SP
188
Setting the SP Upper and Lower Limit Values
191
Set Point Limiter
191
Setting
192
Using the SP Ramp Function to Limit the SP Change Rate
193
SP Ramp
193
Using the Key Protect Level
195
Protection
195
Entering the Password to Move to the Protect Level
196
Displaying Only Parameters that Have Been Changed
198
Displaying Changed Parameters
198
OR Output of Alarms
200
Integrated Alarm
200
Alarm Delays
202
Loop Burnout Alarm (Not Supported for Position-Proportional Models.)
204
Loop Burnout Alarm (LBA)
204
Performing Manual Control
208
Manual MV
208
Using the Transfer Output for the Process Value, Set Point, or Other Data
212
Transfer Output Function
212
Simple Transfer Output Function
215
Using the Simple Program Function
218
Simple Program Function
218
Operation at the Program End
221
Application Example Using a Simple Program
223
Output Adjustment Functions
224
Output Limits
224
MV at Stop
224
MV at PV Error
225
Using the Extraction of Square Root Parameter
227
Extraction of Square Roots
227
Setting the Width of MV Variation
229
MV Change Rate Limit
229
Setting the PF Key
231
PF Setting (Function Key)
231
Displaying PV/SV Status
234
PV and SV Status Display Functions
234
Using a Remote SP
236
Controlling Valves (Can be Used with a Position-Proportional Model)
238
Logic Operations
241
The Logic Operation Function (CX-Thermo)
241
Using Logic Operations
241
Using Status Display Messages
249
Initializing Settings
251
Conventions Used in this Section
254
Protect Level
255
Operation Level
259
Adjustment Level
270
Monitor/Setting Item Level
290
Manual Control Level
291
Initial Setting Level
293
Advanced Function Setting Level
312
Communications Setting Level
347
User Calibration
349
Parameter Structure
351
Thermocouple Calibration
352
Resistance Thermometer Calibration
355
Calibrating Analog Input
357
Calibrating the Transfer Output
361
Checking Indication Accuracy
363
Appendices
367
Specifications
368
Ratings
368
A-1-2 Characteristics
370
Rating and Characteristics of Options
371
A-1-4 Waterproof Packing
372
A-1-5 Unit Labels
372
A-1-6 Setup Tool Port Cover for Front Panel
373
Current Transformer (CT
374
A-2-1 Specifications
374
A-2-2 Dimensions (Unit: MM
374
USB-Serial Conversion Cable and Conversion Cable
375
A-3-1 E58-CIFQ2 USB-Serial Conversion Cable
375
A-3-2 E58-CIFQ2-E Conversion Cable
376
Error Displays
377
Troubleshooting
381
Parameter Operation Lists
385
A-6-1 Operation Level
385
A-6-2 Adjustment Level
386
A-6-3 Initial Setting Level
388
A-6-4 Manual Control Level
392
A-6-5 Monitor/Setting Item Level
392
A-6-6 Advanced Function Setting Level
392
A-6-7 Protect Level
398
A-6-8 Communications Setting Level
398
A-6-9 Initialization According to Parameter Changes
399
Sensor Input Setting Range, Indication Range, Control Range
403
Setting Levels Diagram
404
Parameter Flow
406
Index
409
Omron E5DC Communications Manual (224 pages)
Digital Temperature Controllers. E5*C series
Brand:
Omron
| Category:
Temperature Controller
| Size: 15 MB
Table of Contents
Preface
3
Terms and Conditions Agreement
4
Application Considerations
5
Disclaimers
5
Safety Precautions
6
Definition of Precautionary Information
6
Symbols
6
Precautions for Safe Use
9
Trademarks
12
Versions
13
Revision History
14
H175-E1
14
Sections in this Manual
17
How this Manual Is Organized
17
Related Manuals
17
Communications Methods
17
Table of Contents
18
Overview of Communications Methods
24
Introduction
24
Communications Specifications
24
Transmission Procedure
26
Interface
26
Wiring
27
Communications Parameters
30
Communications Parameter Setup
31
Description of Communications Parameters
32
Compoway/F Communications Procedures
33
Data Format
34
Command Frame
34
BCC Calculation Example
35
Response Frame
35
Communications Data
36
End Code Example
36
Structure of Command Text
38
PDU Structure
38
Area Definitions
38
Type Code (Variable Type)
38
Addresses
39
Number of Elements
39
List of Services (Main Request Codes and Sub-Request Codes)
39
Detailed Description of the Services
40
Read Variable Area
40
Write Variable Area
41
Composite Read from Variable Area
42
Composite Write to Variable Area
44
Read Controller Attributes
45
Read Controller Status
46
Echoback Test
47
Operation Command
48
Response Code List
53
Communications Data for Compoway/F
55
Section 3 Communications Data for Compoway/F
56
Variable Area (Setting Range) List
56
Status and Status 2
77
Section 4 Modbus Communications Procedure
82
Data Format
82
Command Frame
82
Response Frame
84
Error Codes
85
Function List
86
Variable Area
87
Detailed Description of the Functions
88
Variable Read, Multiple
88
Variable Write, Multiple
90
Variable Write, Single/Operation Command
92
Echoback Test
95
Communications Data for Modbus
97
Section 5 Communications Data for Modbus
98
Variable Area (Setting Range) List
98
Status
113
Programless Communications
115
6-1 Programless Communications
117
Introduction
117
Features
117
Programless Communications
117
Operation for Programless Communications
118
Timing of Turning Power on and off
118
Connectable Plcs
119
E5C Setup
121
Protocol Setting
121
Communications Unit No. and Communications Baud Rate
122
Send Data Wait Time
122
Highest Communications Unit no
122
Areas and First Address of Linked Data
123
Receive Data Wait Time
125
Communications Node Number
125
Upload Settings and Download Settings
126
Copying Parameter Settings
128
Communications Writing
130
Communications Monitor Parameter
131
Controlling Programless Communications
132
Controlling Programless Communications with the Request Flag
132
Response Flag
133
Range of Operation for Programless Communications
134
Operation Command Codes
134
Confirming Operation of Programless Communications
134
Write Mode
135
Troubleshooting
135
Connecting to CP-Series Plcs
136
Configuration and Procedure
136
Switch Settings and Wiring
137
PLC Setup
137
E5@C Controller Setup
140
Checking Operation
142
Connecting to CJ-Series Plcs
147
Configuration and Procedure
147
Switch Settings and Wiring
148
PLC Setup
148
E5@C Controller Setup
151
Checking Operation
151
Connecting to the NX1P2
152
Configuration and Procedure
152
Switch Settings and Wiring
153
PLC Setup
153
E5@C Controller Setup
157
Checking Operation
157
Connecting to NJ-Series Plcs
163
Configuration and Procedure
163
Switch Settings and Wiring
164
PLC Setup
164
E5@C Controller Setup
167
Checking Operation
167
Connecting to MELSEC Q-Series Plcs
168
Configuration and Procedure
168
Wiring
169
PLC Setup
169
E5@C Controller Setup
174
Checking Operation
175
Connecting to MELSEC-FX-Series Plcs
180
Configuration and Procedure
180
Wiring
181
PLC Setup
181
E5@C Controller Setup
186
Checking Operation
186
Connecting to MELSEC Iq-R-Series Plcs
187
Configuration and Procedure
187
Wiring
188
PLC Setup
189
E5@C Controller Setup
195
Checking Operation
196
Connecting to Keyence KV-Series Plcs
201
Configuration and Procedure
201
Wiring
202
PLC Setup
202
E5@C Controller Setup
203
Checking Operation
203
Component Communications
207
7-1 Component Communications
208
Introduction
208
Wiring
208
E5@C Setup
209
Operation for Component Communications
212
Troubleshooting
213
Section a Appendices
215
Appendices
215
A-1 ASCII List
215
Troubleshooting
217
Index
219
Advertisement
Omron E5DC Manual (140 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 42 MB
Table of Contents
New Product
2
Digital Temperature Controller
2
Plug-In Models
2
Model Number Legend
4
Heating and Cooling Control
4
Specifications
6
Input Ranges
7
Analog Input
7
Alarm Type
8
Description of Function
8
Communications Specifications
11
Communications Functions
11
External Connections
12
Current Transformers
15
Connection Example
16
Mounting Adapter
17
Terminal Covers
17
Digital Temperature Controller
19
Model Number Legend
20
Heating and Cooling Control
20
List of Models
22
Input Ranges
25
Analog Input
25
Alarm Types
26
Communications Specifications
30
Communications Functions
30
Terminal Covers
35
Current Transformers
36
Connection Example
37
Mounting Adapter
39
Protective Cover
39
Digital Temperature Controller
41
Model Number Legend
42
Heating and Cooling Control
42
Current Transformers (Cts)
44
Input Ranges
46
Analog Input
46
Alarm Types
47
Description of Function
47
Communications Specifications
50
Communications Functions
50
Current Transformers
57
Connection Example
58
Model Number Legend
60
Heating and Cooling Control
60
List of Models
60
Input Ranges
64
Analog Input
64
Alarm Types
65
Description of Function
65
Communications Specifications
68
Communications Functions
68
External Connections
69
Terminal Unit
73
Conversion Cable
73
Current Transformers
74
Connection Example
75
Mounting Adapters
76
Unit Labels
76
Connector Cover
77
Model Number Legend
80
Heating and Cooling Control
80
Input Ranges
83
Analog Input
83
Input Specification
83
Program Control
87
Communications Specifications
88
Communications Functions
88
External Connections
89
Current Transformers
92
Connection Example
93
Operation
115
Setting Levels Diagram
115
Monitor/Setting Item Level
118
Safety Precautions
123
Warning Indications
123
Precautions for Safe Use
123
Shipping Standards
125
Application Conditions
125
Installation Location
125
Measurement Accuracy
126
Operating Precautions
126
Removing the Main Unit
128
Mounting the Terminal Cover
131
Precautions When Wiring
132
Checking Connections
133
Removing Wires from the Push-In Plus Terminal Block
135
Scope of Guarantee
136
Terms and Conditions Agreement
138
Omron E5DC Manual (138 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 42 MB
Table of Contents
Digital Temperature Controller
2
Model Number Legend
3
Heating and Cooling Control
3
Specifications
5
Input Ranges
6
Analog Input
6
Alarm Type
7
Description of Function
7
Communications Specifications
10
Communications Functions
10
External Connections
11
Current Transformers
14
Connection Example
15
Mounting Adapter
16
Terminal Covers
16
Digital Temperature Controller
18
Model Number Legend
19
Heating and Cooling Control
19
List of Models
21
Input Ranges
24
Analog Input
24
Alarm Types
25
Communications Specifications
29
Communications Functions
29
Terminal Covers
34
Current Transformers
35
Connection Example
36
Mounting Adapter
38
Protective Cover
38
Digital Temperature Controller
40
Model Number Legend
41
Heating and Cooling Control
41
Current Transformers (Cts)
43
Input Ranges
45
Analog Input
45
Alarm Types
46
Description of Function
46
Communications Specifications
49
Communications Functions
49
Current Transformers
56
Connection Example
57
Model Number Legend
59
Heating and Cooling Control
59
List of Models
59
Input Ranges
63
Analog Input
63
Alarm Types
64
Description of Function
64
Communications Specifications
67
Communications Functions
67
External Connections
68
Terminal Unit
72
Conversion Cable
72
Current Transformers
73
Connection Example
74
Mounting Adapters
75
Unit Labels
75
Connector Cover
76
Model Number Legend
79
Heating and Cooling Control
79
Input Ranges
82
Analog Input
82
Program Control
86
Communications Specifications
87
Communications Functions
87
External Connections
88
Current Transformers
91
Connection Example
92
Operation
114
Setting Levels Diagram
114
Safety Precautions
122
Warning Indications
122
Precautions for Safe Use
122
Shipping Standards
124
Application Conditions
124
Installation Location
124
Measurement Accuracy
125
Operating Precautions
125
Removing the Main Unit
127
Mounting the Terminal Cover
130
Precautions When Wiring
131
Checking Connections
132
Removing Wires from the Push-In Plus Terminal Block
134
Scope of Guarantee
135
Omron E5DC Manual (56 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 7 MB
Table of Contents
Digital Temperature Controller
2
Heating and Cooling Control
4
Table of Contents
5
Input Ranges
7
Alarm Outputs
8
External Connections
12
E58-Cifq2
13
Terminal Covers
13
E53-Cov17
13
E53-Cov23
13
Waterproof Packing
14
Y92S-P8
14
Current Transformers (Cts)
14
E54-Ct1
14
E54-Ct3
14
Connection Example
14
Digital Temperature Controller
17
Heating and Cooling Control
18
CX-Thermo Support Software
19
Model EST2-2C-MV4
19
For the System Requirements for the CX-Thermo, Refer to
19
Information on the EST2-2C-MV4 on the OMRON Website
19
(Www.ia.omron.com)
19
Input Ranges
21
Alarm Type
22
External Connections
26
Connection Example
31
List of Models
34
Specifications Ratings
36
Alarm Types
38
Safety Precautions
51
Warning Indications
51
Precautions for Safe Use
52
Removing the Main Unit
54
Warranty
56
Omron E5DC Manual (58 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 7 MB
Table of Contents
Digital Temperature Controller
2
Heating and Cooling Control
3
Input Ranges
6
Alarm Outputs
7
External Connections
11
Connection Example
13
Digital Temperature Controller
16
Heating and Cooling Control
17
Input Ranges
20
Alarm Type
21
External Connections
25
Connection Example
30
List of Models
33
Specifications Ratings
35
Alarm Types
37
Safety Precautions
50
Warning Indications
50
Precautions for Safe Use
51
Removing the Main Unit
53
Warranty
55
Omron E5DC Manual (27 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 3 MB
Table of Contents
Heating and Cooling Control
2
Mounting Adapters
3
Specifications
4
Input Ranges
5
Alarm Type
6
Description of Function
6
Communications Specifications
9
External Connections
10
Conversion Cable
12
Connection Example
12
Operation
14
Setting Levels Diagram
14
Monitor/Setting Item Level
17
Safety Precautions
18
Warning Indications
18
Precautions for Safe Use
18
Application Conditions
20
Installation Location
20
Removing the Main Unit
21
Mounting the Terminal Cover
22
Scope of Guarantee
23
Terms and Conditions of Sale
25
Omron E5DC Manual (16 pages)
Digital Temperature Controller
Brand:
Omron
| Category:
Temperature Controller
| Size: 1 MB
Table of Contents
Model Number Legend
2
List of Models
2
Heating and Cooling Control
2
Specifications
4
Input Ranges
5
Analog Input
5
Description of Function
6
Alarm Types
6
Communications Specifications
9
Communications Functions
9
External Connections
10
Terminal Unit
12
Conversion Cable
12
Current Transformers
13
Connection Example
14
Mounting Adapters
15
Unit Labels
15
Omron E5DC Instruction Manual (2 pages)
Digital Controller
Brand:
Omron
| Category:
Controller
| Size: 2 MB
Advertisement
Related Products
Omron E5DC-800
Omron E5DC-B
Omron E5DC-RX0ASM-015
Omron E5DC-RX2ASM-000
Omron E5DC-RX2ASM-002
Omron E5DC-RX2ASM-017
Omron E5DC-QX0ASM-015
Omron E5DC-QX2ASM-000
Omron E5DC-QX2ASM-002
Omron E5DC-QX2ASM-017
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL