6 Parameters
Advanced Function Setting Level
Page
Parameter
6-63
init
Initialization
off
M
mspu
Number of
6-63
Multi-SP Points
off
M
SP Ramp Time
spru
6-63
Unit
m
M
Standby
rest
6-64
Sequence
a
Reset
M
sb1n
6-65
Auxiliary Output
1 Open in Alarm
n-o
M
sb2n
6-65
Auxiliary Output
2 Open in Alarm
n-o
M
sb3n
6-65
Auxiliary Output
3 Open in Alarm
n-o
M
Auxiliary Output
6-65
sb4n
4 Open in Alarm
n-o
M
6-65
hbu
HB ON/OFF
on
M
Heater Burnout
hbl
6-66
Latch
off
M
hbh
Heater Burnout
6-66
Hysteresis
0.1
M
st-b
ST Stable
6-67
Range
15.0
M
α
alfa
6-67
0.65
M
Integral/Derivative
tidu
6-67
Time Unit
1
M
at-g
6-68
AT Calculated
Gain
0.8
000
M
6-68
at-h
AT Hysteresis
0.8
000
M
lcma
Limit Cycle MV
6-68
Amplitude
000
20.0
M
inf
6-68
Input Digital
Filter
0.0
M
Moving Average
mav
6-69
Count
off
M
FB Moving
6-69
pmav
Average Count
16
800
M
MV Display
o-dp
6-70
off
M
Automatic
ret
6-70
Display Return
off
Time
M
brgt
Display
6-70
Brightness
000
3
M
6 - 62
Page
6-71
a1lt
Alarm 1 Latch
off
M
6-71
a2lt
Alarm 2 Latch
off
M
a3lt
6-71
Alarm 3 Latch
off
M
6-71
a4lt
Alarm 4 Latch
off
M
prlt
6-72
Move to Protect
Level Time
3
M
cjc
Cold Junction
6-72
Compensation
on
Method
M
a1on
6-73
Alarm 1 ON
Delay
0
M
a2on
6-73
Alarm 2 ON
Delay
0
M
a3on
Alarm 3 ON
6-73
Delay
0
M
a4on
6-73
Alarm 4 ON
Delay
0
M
a1of
6-74
Alarm 1 OFF
Delay
0
M
a2of
6-74
Alarm 2 OFF
Delay
0
M
a3of
Alarm 3 OFF
6-74
Delay
0
M
a4of
6-74
Alarm 4 OFF
0
Delay
M
MV at Stop and
mvse
6-74
Error Addition
off
000
M
Auto/Manual
amad
6-75
Select
off
Addition
M
Manual Output
mant
6-75
Method
hold
M
Manual MV Initial
mani
6-76
Value
0.0
M
RT
rt
000
6-77
off
M
hsu
6-77
HS Alarm Use
on
M
HS Alarm Latch
hsl
6-78
off
M
HS Alarm
hsh
6-78
Hysteresis
0.1
M
Page
6-79
lba
LBA Detection
Time
0
M
LBA Level
lbal
6-79
8.0
M
lbab
6-80
LBA Band
3.0
M
Control Output 1
6-81
out1
Assignment
o
M
Control Output 2
6-81
out2
Assignment
none
M
sub1
Auxiliary Output 1
6-82
Assignment
alm1
M
sub2
6-82
Auxiliary Output 2
alm2
Assignment
M
6-82
sub3
Auxiliary Output 3
Assignment
alm3
M
Auxiliary Output 4
6-82
sub4
Assignment
alm4
000
M
Integrated Alarm
alma
6-83
Assignment
49
M
t-u
6-84
Soak Time Unit
000
m
M
6-84
alsp
Alarm SP
Selection
000
sp-m
M
Remote SP
6-85
rs-t
Input
000
4-20
M
Remote SP
6-85
rspu
Enable
000
off
M
Remote SP
rsph
6-86
Upper limit
000
1300
M
Remote SP
6-86
Rrspl
000
Lower limit
-200
M
SP Tracking
6-87
sptr
000
off
M
6-87
p-db
PV Dead Band
0
M
Manual MV Limit
manl
6-88
Enable
000
off
M
6-88
Direct Setting of
pmvd
Position
off
Proportional MV
M
PV Rate of
6-88
pvrp
Change Calculation
20
Period
M
Heating/Cooling
6-89
hctm
Tuning Method
off
M
E5@C Digital Temperature Controllers User's Manual (H174)
Page
Minimum Output
ompw
6-89
ON/OFF Band
1.0
M
PF Setting
pf
6-90
shft
M
pfd1
6-91
Monitor/Setting
Item 1
1
000
M
pfd2
6-91
Monitor/Setting
Item 2
0
000
M
pfd3
6-91
Monitor/Setting
Item 3
000
0
M
pfd4
6-91
Monitor/Setting
Item 4
0
000
M
pfd5
6-91
Monitor/Setting
Item 5
000
0
M
6-92
spd1
PV/SP No. 1
Display Selection
4
M
spd2
PV/SP No. 2
6-92
Display Selection
0
M
MV Display
odsl
6-92
Selection
o
M
PV Decimal
pvdp
6-93
Point Display
on
000
M
pvst
PV Status
6-93
Display Function
off
M
svst
6-94
SV Status
Display Function
off
M
d.ref
6-94
Display Refresh
Period
0.25
M
LCT Cooling
lcmt
6-95
Output Minimum
0.2
ON Time
M
Move to
cmov
6-95
Calibration Level
0
000
M