Digital Temperature Controller
E5DC
The E5DC Mounts to DIN Track and Is Ideal
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and
Advanced Performance as the Rest of the
E5@C Series.
• A slim body at 85 × 22.5 mm (D × W) that fits into narrow control
panels and mounts to DIN Track.
• Removable terminal block for easy replacement to simplify maintenance.
• High-speed sampling at 50 ms for applications with high-speed
temperature increases.
• Easy connections to a PLC with programless communications.
• Set up the Controller without wiring the power supply by connecting
to the computer with a Communications Conversion Cable (sold separately).
Setup is easy with the CX-Thermo (sold separately).
• Models are available with up to 2 auxiliary outputs and 1 event input to
complete basic functions.
• A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel.
Main I/O Functions
Sensor Input
Universal input
• Thermocouple
• Pt
• Analog current/voltage
Indication Accuracy
• Thermocouple input:
±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input:
±0.2% of FS
Sampling Period
• 50 ms
Event Inputs
• None
• 1
Serial Communications
• None
• RS-485
This datasheet is provided as a guideline for selecting products.
Be sure to refer to the following manuals for application precautions and other information required for operation before attempting
to use the product.
E5@C Digital Temperature Controllers User's Manual (Cat. No. H174)
E5@C Digital Temperature Controllers Communications Manual (Cat. No. H175)
58
(22.5 mm Wide, and DIN Track-mounting Type)
• PF (shift) Key
• Temperature status display
• Simple programming
• Independent heating and
cooling PID control
• Changed parameter display
• Display brightness setting
Refer to your OMRON website for the most recent
information on applicable safety standards.
E5DC
22.5 mm Wide, and
DIN Track-mounting Type
E5DC
Refer to Safety Precautions on page 118.
Dual displays: PV/SV
4-digit displays
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Linear current output
Auxiliary Outputs
• None
• 2

Advertisement

Table of Contents
loading

Summary of Contents for Omron E5DC

  • Page 1 Digital Temperature Controller E5DC (22.5 mm Wide, and DIN Track-mounting Type) The E5DC Mounts to DIN Track and Is Ideal for Connections to HMIs and PLCs. It provides the Same Easy Operation and Advanced Performance as the Rest of the E5@C Series.
  • Page 2: Model Number Legend

    E5DC Model Number Legend and Standard Models Model Number Legend Models with Screw Terminal Blocks E5DC-@@ @ @ @ M-@@@ (Example: E5DC-RX0ASM-015) −− − − − − −−− B C D E No. of Power Model Meaning Control Terminal Input...
  • Page 3 Short Bars Model Y92S-P11 (4 pcs) CX-Thermo Support Software Model EST2-2C-MV4 Note: CX-Thermo version 4.6 or higher is required for the E5DC. For the system requirements for the CX-Thermo, refer to information on the EST2-2C-MV4 on the OMRON website (www.ia.omron.com).
  • Page 4: Specifications

    E5DC Specifications Ratings A in model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 4.9 VA max. at 100 to 240 VAC, and 2.8 VA max. at 24 VDC or 1.5 W max. at 24 VDC...
  • Page 5: Input Ranges

    E5DC Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Sensor Platinum resistance Infrared temperature Thermocouple type thermometer sensor Sensor 10 to 60 to 115 to 140 to Pt100 JPt100 C/W PLII 70°C 120°C 165°C 260°C specification 2300 2300 1800 1800 1700...
  • Page 6: Description Of Function

    E5DC Alarm Types Each alarm can be independently set to one of the following 17 alarm types. The default is 2: Upper limit. (See note.) Auxiliary outputs are allocated to alarms. ON delays and OFF delays (0 to 999 s) can also be specified.
  • Page 7 E5DC *1. With set values 1, 4, and 5, the upper- and lower-limit values can *4. Set value: 5, Upper- and lower-limit with standby sequence be set independently for each alarm type, and are expressed as For Upper- and Lower-Limit Alarm Described Above at *2 “L”...
  • Page 8 Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.6 or higher E5DC bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port on the computer. *6 Setup Tool port E5DC front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion Cable are used together to connect a USB port on the computer.*6...
  • Page 9: Communications Specifications

    E5DC USB-Serial Conversion Cable When Digital Temperature Controllers are connected, set points and RUN/STOP commands can be sent Windows XP/Vista/7/8/10 *1 Applicable OS from the Digital Temperature Controller that is set as Component Applicable software CX-Thermo version 4.6 or higher...
  • Page 10: External Connections

    External Connections E5DC Control output Auxiliary outputs 1, 2 The E5DC is set for a K-type thermocouple (input type = 5) by default. Relay outputs Relay output An input error (s.err) will occur if the input type setting does not agree 250 VAC: 2 A (resistive load) with the temperature sensor.
  • Page 11 E5DC Nomenclature E5DC Front panel Bottom View of E5DC No. 1 display PV or specified parameter Operation indicators No.2 display SP or specified parameter value Press O Key once to go to Use the M Key to change to another Adjustment Level.
  • Page 12: Terminal Unit

    E5DC Accessories (Order Separately) Terminal Unit E5DC-SCT1S 22.5 30.7 USB-Serial Conversion Cable E58-CIFQ2 (2110) 1510 LED (RD) USB connector (type A plug) Serial connector LED (PWR) LED (SD) Conversion Cable E58-CIFQ2-E Conversion Cable Connecting to the E58-CIFQ2 USB-Serial Conversion Cable...
  • Page 13: Current Transformers

    E5DC Current Transformers E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Filler E54-CT1 or E54-CT1L 5.8 dia. (epoxy) Maximum continuous heater current: 50 A (50/60 Hz) Case ± Number of windings: ± Ω Winding resistance: 10.5 100V Frequency: 50 Hz ∞...
  • Page 14: Connection Example

    Filler 12 dia. (epoxy) E54-CT3 or E54-CT3L Case Maximum continuous heater current: 120 A (50/60 Hz) (PBT) (Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A.) 40 × 40 Number of windings: 400±2 Ω Winding resistance: 8±0.8...
  • Page 15: Mounting Adapters

    Meter are used. Use either the °C or °F label from the sheet. 34.8 44.3 16.5 End Cover Y92F-54 (Two included.) Use the End Cover when you mount the E5DC to a panel to hide the gap between the Controller and the panel.