Hyundai Sonata 1991 Shop Manual page 178

Table of Contents

Advertisement

Display when vehicle speed is
approximately 20 km/h (12 mph) or higher,
or before the ASC system is set
AUTOMATIC SPEED CONTROL (CRUISE)
Diagnosis Display Patterns and Codes
Code
Display patterns (output codes)
Probable cause
No.
(Use with voltmeter)
11
Abnormal condition of actuator drive system
12V~
OV
12
Abnormal condition of vehicle-speed signal system
12V~
OV
13'
1 2 V ~
Low-speed limiter activation (The system is normal if it can be
reset.)
OV
14'
12V
1
4
Automatic cancellation activated by vehicle speed reducion. (The
OV~
system is normal if it can be reset)
15'
12V
t
~~h~
Control switch malfunction (when SET and RESUME switches
switched ON simultaneously)
OV
16'
12V
,
6m~
Cancel switch ON signal input (including stop lamp switch input
m~1
wiring damage or disconnection)
OV
,~
NOTE
1.
Codes indicated by the' symbol are displayed, if the conditions are satisfied, even if the system is normal.
In either case, the system is normal if it can be reset. If there is an automatic cancellation not intentionally
made by the driver, however, excluding cancellations explicitly made by the cancel procedure, there may
be a temporary malfunction such as poor contact of a harness connector even though the system can be
reset, and for that reason it is necessary to check according to each individual check chart that is applicable.
2.
Diagnosis codes are displayed when, after cancellation of the ASC system, the vehicle speed decreases
to less than approximately 20 km/h (12 mph), and are erased by switching OFF the ignition switch or
the MAl N switch. After the diagnosis codes in the memory are erased, if (when the power supply of the
electronic control unit is switched ON once again) the
power supply of the electronic control unit is normal, the
diagnosis output code display will be as below, regardless
of whether the system condition is normal or not.
1)
If a multi-use tester is used:
"NORMAL!!" will be displayed.
2)
If a voltmeter is used:
Continuous ON/OFF signals will be displayed at
0.5-second intervals.
(Refer to the figure at the right.)
0.5
se~.5
sec
ON
I I I
112VI
~ ~ ~
E:' i l
~ ~
f:I
~
_
OFF~
IOV)
27-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents