CHARGING SYSTEM
Check specific gravity.
Refer to "Specific gravity check chart"
for electrolyte temperature compensation, and
then select proper reading below.
I
Below 1.100
1.100 -
1.220
Above 1.220
I
Slow charge
Recharge
Perform load test
Slow charge battery at 6A for no
Refer to charging guide and safety
more than
14 hrs., and then
precautions
perform load test.
I
Load test battery
Apply 200A load for 15 sec., then check battery
voltage and compare below
I
Above 9.6 volts
I
9.6 -
6.5 volts
I I
Below 6.5 volts
I
I
I
I
Battery O.K. reuse
Fast charge
battery and then
perform load test again.
NOTE: If battery is still less then
9.8 volts after second fast charge
and load test, then it should be
replaced
Battery no good.
Replace
27-18