RADIATOR FAN MOTOR ASSY
Thermo Sensor A
Check for continuity with the thermo sensor in hot water.
NOTE:
Immerse the thermo sensor in hot water up to the mounting
threads to check for continuity.
Operating temperature
OFF - ON
87-93°C (189-199°F)
ON - OFF: 83°C or more (181°F or more)
25Y019
ON
OFF
~----r----r"
ON
L..-._-,4.---L.,
..1..-
Water
temperature
OFF
83°C
90±3°C
25Y020
Thermo Sensor B
Operating temperature
OFF - ON
108°C or more (226°F or more)
ON - OFF: 112-118°C (234-244°F)
INSTALLATION
Y25GCOA
OFF
ON
1
OFF
-----/:
7
I
I
Water
ON
108°C
115±3°C
temperature
25Y043
1.
Installation is in the reverse order of removal procedures.
CAUTION:
1) Make sure the cooling fan does not come into contact
with the &hroud when installed.
2) After installation, make sure there is no unusual noise
or vibration when the fan is rotated.
J ; f - -
.-/
O
25Y021
25-13