Vap Wds Only (Access Point); No Vap Wds Only (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.1 WLAN
7.1.6.5

vap wds only (access point)

Description
With this command, you specify that the access point only supports communication via WDS.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
vap wds only
Result
You have specified who the VAP interface connects to.
Further notes
You display the setting with the show wlan vap <vap X 0/Y>command.
You disable the function with the no vap wds only command (default setting).
See also
no vap wds only (access point) (Page 268)
7.1.6.6

no vap wds only (access point)

Description
With this command, you specify that the access point supports not only communication via
WDS. This setting is activated as default.
Note
This command is available only in access point mode.
268
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents