Wlan Ipcf-Ht Protocol-Support (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Functions specific to SCALANCE
5.5 iPCF-HT
5.5.2.3

wlan ipcf-ht protocol-support (Access Point)

Note
This command is only available with the following KEY-PLUG:
● W780 iFeatures (MLFB 6GK5 907-8PA00)
Description
With this command, you enable the optimized support of PROFINET or Ethernet/IP.
Frames with the selected protocol are preferred.
Requirement
The SCALANCE W700 device is in access point mode.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ipcf-ht protocol-support {pnio | ethernet-ip}
Parameter
pnio
ethernet-ip
Result
The optimized support of PROFINET or Ethernet/IP is enabled.
Further notes
You disable the optimized support with the no wlan ipcf-ht protocol-support
command.
You display the setting with the show wlan ipcf-ht command.
134
Description
Keyword for the PROFI‐
NET
Keyword for the Ether‐
Net/IP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note