4.1.11.6

no lldp

Description
With this command, you disable the sending and receipt of LLDP packets on the interface.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no lldp{transmit|receive}
The parameters have the following meaning:
Parameters
transmit
receive
Note
Disabling both options
When you call this command, you can only select one option.
If you want to disable both options, call up the command again.
Result
The setting is configured.
Further notes
You enable the sending or receipt of LLDP packets with the lldp command.
You display the status of LLDP with the show lldp status command.
4.1.11.7

mtu

Description
With this command, you configure the size of the Maximum Transmission Unit (MTU) for an
interface.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
the sending of LLDP packets is enabled
the receipt of LLDP packets is disabled
Configuration
4.1 System
79

Hide quick links: