Network protocols
8.6 SNMP
Parameter
read
write
notify
Storage Type
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the show snmp group command.
You display the access configurations for SNMP groups with the show snmp group
access command.
You display the configured SNMP tree views with the show snmp viewtree command.
8.6.2.5

no snmp access

Description
With this command, you delete the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
416
Description
The data can be read.
Keyword
The data can be read and written
Keyword
Changes can be sent as a tag.
Keyword
Specifies whether the settings remain
following a restart.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
● ReadView
● none
● WriteView
● none
● NotifyView
● none
● volatile :
The settings are lost after a
restart
● nonvolatile :
The settings are retained after
a restart