Wlan Mode (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.1 WLAN
Using the show wlan basic command, check whether or not the current WLAN settings
violate the permitted transmit power restrictions (TX Power Check) of the selected country.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan max tx-power <dBm(5-20)>
The parameter has the following meaning:
Parameters
dBm
Result
The transmit power is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
7.1.5.55

wlan mode (access point)

Description
With this command, you specify the transmission standard.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
256
Description
Transmit power in decibel-milliwatts (dBm)
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
5...20
Default: 20
Configuration Manual, 09/2017, C79000-G8976-C324-08