No Auto-Save - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Result
The auto save function is enabled.
Further notes
You save changes to the configuration in the Trial mode with the write startup-config
command.
You disable the function with the no auto-save command.
You can display the status of this function and other information with the show device
informationcommand.
4.4.3.2

no auto-save

Description
With this command, you disable the auto save function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no auto-save
Result
The auto save function is disabled. The Trial mode is activated.
Further notes
You enable the function with the auto-save command.
You can display the status of this function and other information with the show device
informationcommand.
You save changes to the configuration in the Trial mode with the write startupconfig
command.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Configuration
4.4 Configuration Save & Restore
105