switchport priority default

Description
With this command, you configure the priority default for the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
switchport priority default <(0-7)>
The parameter has the following meaning:
Parameter
-
Result
The setting for the default priority of the interface is configured.
Further notes
You reset the priority default to the original default with the no switchport priority
default command.
You display this setting and other information with the show vlan port config command.
7.2.3.7

no switchport priority default

Description
With this command, you reset the priority default for the interface to the default value.
294
Description
Value for the priority default
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
0 ... 7
Default: 0