Network structures
7.1 WLAN
Result
The mode of the SCALANCE W700 device is specified.
Note
If you change the operating mode, the SCALANCE W700 devices needs to be restarted. Before
the device restarts, a prompt for confirmation is displayed. If you confirm the prompt, the
SCALANCE W700 device starts automatically in the new operating mode.
Further notes
You display the settings for the mode with the show wlan device command.
See also
show wlan device (Page 194)
7.1.4.2

commit mode

Description
With this command, you specify when the modified WLAN settings become effective on the
SCALANCE W700 device.
Requirement
You are in the WLAN Configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
commit mode { auto | manual }
The parameters have the following meaning:
Parameters
auto
manual
Result
The commit mode is specified.
206
Description
Each change to the WLAN settings is automatically applied and is immediately effective.
The changes are accepted, but are still not active. The changes only take effect when
you confirm the changes with the "commit wlan-settings" command.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08