No Severity - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Diagnostics
12.1 Diagnostics
12.1.6.13

no severity

Description
With this command, you disable the setting for the threshold values for the sending of system
event notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
no severity { mail | log | syslog | authlog }
The parameters have the following meaning:
Parameter
mail
log
syslog
authlog
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for sending system event messages are configured.
Further notes
You enable the setting with the severity command.
You display the status of this function and other information show events severity.
602
Description
The setting of the threshold value for
sending system event messages by e-
mail is disabled.
The setting of the threshold value for
entering system event messages in the
log table disabled.
The setting of the threshold value the
entering event messages in the Syslog
file is disabled.
The setting of the threshold value for
entering system event messages in the
log table for authentications is disabled.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
-
-
-
-
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading