System time
6.3 SNTP client
Further notes
You can reset the setting to the default with the no sntp unicast-server command.
You display this setting and other information with the show sntp unicast–mode
status command.
6.3.3.3

no sntp unicast-server

Description
With this command, you delete the attributes for an SNTP unicast server and reset the
address.
Requirement
You are in the SNTP configuration mode.
The command prompt is as follows:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
no sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <Fully
Qualified Domain Name(100)> | ipv6 <ip6_addr>}
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
Fully Qualified
Domain Name(100)
ipv6
ip6_addr
Result
The SNTP unicast server is reset to the default value.
Further notes
You configure the setting with the sntp unicast-server command.
You display this setting and other information with the show sntp unicast–mode
status command.
182
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
Value for the IPv6 address of the time
server
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
-
Enter a valid IPv4 unicast address
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
Configuration Manual, 09/2017, C79000-G8976-C324-08