Time Dst Recurring - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Result
The entry for the start and end of daylight saving time was created.
Further notes
You display the settings for the daylight saving time changeover with the show dst info
command.
6.1.2.4

time dst recurring

Description
With this command, you configure the start and end of daylight saving time with a generic
description.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time dst recurring <name(16)> begin {<week(1-5)> | last} <weekday>
<month> <hour> end {<week(1-5)> | last} <weekday> <month> <hour>
The parameters have the following meaning:
Parameter
name
begin
week
last
weekday
month
hour
end
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Name of the entry
Keyword for the start of daylight saving
time.
Calendar week in a month
Keyword for the last calendar week in a
month
Weekday
Month
Hour
Keyword for the end of daylight saving
time.
System time
6.1 System time setting
Range of values / note
maximum 16 characters
-
1 ... 5
-
monday, tuesday, wednesday,
thursday, friday, saturday, sunday
january, february, march, april,
may, june, july, august, septem‐
ber, october, november, december
0 ... 23
-
171

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents