Interface - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Configuration
4.1 System
cli(config)#
Syntax
Call up the command with the following parameters:
ethernetip {off|on}
The parameters have the following meaning:
Parameter
off
on
Result
EtherNet/IP is enabled or disabled after the next restart.
Further notes
You can display the current EtherNet/IP configuration with the show ethernetip command.
You restore the default settings of the EtherNet/IP profile with the restart command.
4.1.10.5

interface

Description
With this command, you change to the Interface Configuration mode.
There you can edit the settings for one interface. You select the interface with the parameters
of this command. If you specify a logical interface that does not exist, it will be created. The
name of the selected interface is displayed in the command prompt.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
68
Description
EtherNet/IP will be disa‐
bled after the next restart.
EtherNet/IP will be ena‐
bled after the next restart.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
-
● When EtherNet/IP is turned on, PROFINET is turned off.
The switchover from EtherNet/IP and PROFINET has no
effect on DCP.
● If a PROFINET connection is established; in other words
the PROFINET AR status is "Online", you cannot enable
EtherNet/IP.
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links: