Power - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

cli(config-events)#
Syntax
Call up the command with the following parameters:
no link {up|down}
The parameters have the following meaning:
Parameters
up
down
Result
The settings for monitoring the physical network connections have been configured.
Further notes
You can display the current setting with the show events faults config command.
You enable the function with the link command.
12.1.6.8

power

Description
With this command, you configure and activate the monitoring of the power supplies.
Depending on the hardware variant there are one or two power connectors (L 1 / L 2) and a
PoE power supply.
Note
This command is not available on the SCALANCE W786-2 SFP.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
power [{l1 | l2 | poe}]
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
The message when establishing a connection is dis‐
abled
The message when a connection is down is disabled -
Diagnostics
12.1 Diagnostics
Range of values / note
-
597

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents