Description
With this command, you specify that clients logged on to different SSIDs of an access point
cannot communicate with each other.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with other-vaps
Result
The communication option via different SSIDs of an access point is disabled.
Note
with other VAPs function disabled
If the "with other VAPs" function is disabled the various WLAN clients can no longer see each
other. This means that Address Collision Detection (ACD) also no longer works reliably.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the vap communication with other-vaps command.
See also
vap communication with other-vaps (access point) (Page 535)