Using The Ladder Diagram To Control The Entire Network - Delta AH500 Manual

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

AH500 Module Manual

11.5.3 Using the Ladder Diagram to Control the Entire Network

Program Explanation::
In segment 1, the curve gain is set to 1 for Channel 1 of AH06XA-5A and AH08DA-5B.
In segment 2, by comparing the input voltage of channel 1 of AH06XA-5A, the Y0.0 indicator is
ON when the voltage is larger than 5 V.
In segment 2, by comparing the input voltage of channel 1 of AH06XA-5A, the Y0.1 indicator is
ON when the voltage is less than 5 V.
11-76