AH5 00 M od ul e M anua l
CR#
Attribute
Base register used for the
26
R/W
sending of data through COM2
Base register used for the
27
R/W
receiving of data through COM2
Triggering the sending/receiving
28
R/W
of groups of packets in
sequence
29~
Reserved
4098
Selecting Enable boxes to
4099~
enable the reading of data from
R/W
bit devices through COM1 (256
4114
values/16 words)
Selecting Enable boxes to
8195~
enable the reading of data from
R/W
word devices through COM1
8210
(256 values/16 words)
Selecting Enable boxes to
12291~
enable the writing of data into bit
R/W
devices through COM1 (256
12306
values/16 words)
Selecting Enable boxes to
16387~
enable the writing of data into
R/W
word devices through COM1
16402
(256 values/16 words)
Selecting Enable boxes to
20483~
enable the reading of data from
R/W
20498
bit devices through COM2 (256
values/16 words)
Selecting Enable boxes to
24579~
enable the reading of data from
R/W
24594
word devices through COM2
(256 values/16 words)
Selecting Enable boxes to
28675~
enable the writing of data into bit
R/W
28690
devices through COM2 (256
values/16 words)
8 - 1 0
Register name
Description
The communication protocol for
exchanging data through COM2 must be
UD Link. Users have to select
Base+Offset in the Mapping Register
box in the Message Variable Edit window
in SCMSoft.
Data register from which data is
read=Value in CR#26+Offset
The communication protocol for
exchanging data through COM2 must be
UD Link. Users have to select
Base+Offset in the Mapping Register
box in the Message Variable Edit window
in SCMSoft.
Data register into which data is
written=Value in CR#27+Offset
0: Not triggering it
1~254: Number of times the
sending/receiving of groups of
packets is triggered in sequence
255: The sending/receiving of groups of
packets is continually triggered in
sequence.
Bit=0: Disabling the reading of data from a
bit device through COM1
Bit=1: Enabling the reading of data from a
bit device through COM1
Bit=0: Disabling the reading of data from a
word device through COM1
Bit=1: Enabling the reading of data from a
word device through COM1
Bit=0: Disabling the writing of data into a
bit device through COM1
Bit=1: Enabling the writing of data into a bit
device through COM1
Bit=0: Disabling the writing of data into a
word device through COM1
Bit=1: Enabling the writing of data into a
word device through COM1
Bit=0: Disabling the reading of data from a
bit device through COM2
Bit=1: Enabling the reading of data from a
bit device through COM2
Bit=0: Disabling the reading of data from a
word device through COM1 (256
values/16 words)
Bit=1: Enabling the reading of data from a
word device through COM2 (256
values/16 words)
Bit=0: Disabling the writing of data into a
bit device through COM1 (256
values/16 words)
Bit=1: Enabling the writing of data into a bit