12. Double click the 10PFBM icon in the HWCONFIG window; the "Parameter Setting" dialog box
pops up and then click "Normal Exchange Area" tab as below.
(Note: For details on the registers in normal exchange area, see the following table
"Explanation of corresponding registers in the normal exchange area in AH10PFBM-5A".)
13. Double click the 10PFBM icon and then the Parameter Setting dialog box pops up.
Set Input Area D Begin Address, Input Area D Length, Output Area D Begin Address and
Output Area D Length by clicking the place marked in red box below. .
(If the selected D device range is occupied, the system will remind that the device range setting
conflicts and user should reset it). The data in OUTPUT area are transmitted to the slave and
the INPUT area receives the data from the slave. Click "OK" to complete the parameter
configuration。
Ch a pt er 1 2 N e t wor k Mo d u le AH 10 P F BM