Delta AH500 Manual page 257

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

Ch ap te r 7 High-s pee d C oun ter Modu le AH0 2HC /AH0 4HC
(1) Linear accumulation:
If an accumulation register counts up, it counts from 0 to 999999999. If an accumulation
register counts down, it counts from 0 to -999999999.
If the value in an accumulation register is larger than the maximum value 999999999 or less
than the minimum value -999999999, the value in the accumulation register will be
999999999 or -999999999, and bit 1 in CR19/CR47/CR75/CR103 will be turned ON. Users
can read the error code 16#A0n1 in CR26/CR54/CR82/CR110. (n is a channel number. n:
0~3 (i.e. channel 0~channel 3))
O p e r ati o n o f a co un te r
b i t0 (p a r am e ter s for o p e ra ti o n)
The line ar acc umulation is equa l to
the maximum va lue or the min imum v alue.
bi t2 ( p ar a me te r s fo r op e r at io n sta te )
The res etting value of th e lin ear ac cumulation,
of the ac c umula tion regis ter, pulse input reg is ter,
or th e lin ear ac cumulation is equ al to the max imum
va lue or the min imum value.
b it 2 (p a ra me te r s fo r o pe r a tio n )
If the linear accumulation is larger than the maximum value 999999999 or less than the
minimum value -999999999 in the count cycle, the value stored in the accumulation register
will be 999999999 or -999999999, bit 1 in CR19/CR47/CR75/CR103 will be turned ON.
Users can read the error code 16#A0n1 in CR26/CR54/CR82/CR110. (n is a channel
number. n: 0~3 (i.e. channel 0~channel 3)) If bit 1 in CR0/CR28/CR56/CR84 is turned ON,
the sampling register/accumulation register/pulse input register, and bit 1 in
CR19/CR47/CR75/CR103 will be reset. After the sampling register/accumulation
register/pulse input register, and bit 1 in CR19/CR47/CR75/CR103 is reset, bit 1 in
CR0/CR28/CR56/CR84 will be turned OFF automatically.
The related parameters are described below.
Item
Number of
accumulated pulses
(Low word)
Number of
accumulated pulses
(High word)
Operating state of a
counter
Operation of a
counter
N u mb e r o f a ccu mu l at ed p u lse s*
9 9 99 9 99 99
o r
- 99 9 99 99 9 9
0
O N
OFF
OFF
OFF
* : Th e c y c le of u pdatin g th e n umb er of s ampl ed pu ls es i s the c y c le s et.
Value/Setting value
-999999999~999999999
Bit 1: The linear
accumulation is larger than
the maximum value or less
than the minimum value.
Bit 1: Resetting the
sampling
register/accumulation
register/pulse input register,
and bit 1 in
CR19/CR47/CR75/CR103
O N
O N
Parameter
CH0
CH1
CH2
#22
#50
#78
#23
#51
#79
#19
#47
#75
#0
#28
#56
Tim e
CH3
#106
#107
#103
#84
7 - 2 5