write
[DEFAULT@Router /config/]#rmon
Key Word:
U(undo)
D(default)
(00)alarm
(01)event
Please Input the code of command to be excute(0-1): 0
Key Word:
Q(quit)
(00)<1-65535>
Please Input the code of command to be excute(0-0): 0
Please input a digital number:100 (input alarm number)
Key Word:
Q(quit)
(00)WORD
Please Input the code of command to be excute(0-0): 0
Please input a string:abc (input MIB object)
Key Word:
Q(quit)
(00)<1-4294967295>
Please Input the code of command to be excute(0-0): 0
Please input a digital number:500 (input interval)
Key Word:
Q(quit)
(00)absolute
(01)delta
Please Input the code of command to be excute(0-1): 0
Key Word:
Q(quit)
(00)rising-threshold
Please Input the code of command to be excute(0-0): 0
Key Word:
Q(quit)
(00)<-2147483648-2147483647>
Please Input the code of command to be excute(0-0): 0
Please input a string:10000 (input rising threshold value )
Key Word:
Q(quit)
(00)falling-threshold
(01)<1-65535>
Please Input the code of command to be excute(0-1): 0
Key Word:
Q(quit)
(00)<-2147483648-2147483647>
Please Input the code of command to be excute(0-0): 0
Please input a string:100000 (input falling threshold value )
Key Word:
Q(quit)
(00)<1-65535>
(01)owner
(02)<CR>
Please Input the code of command to be excute(0-2): 1
Key Word:
Q(quit)
(00)WORD
Please Input the code of command to be excute(0-0): 0
Please input a string:dlink (input alarm owner)
Will you excute it? (Y/N):y
Model Name
Save the configuration
Q(quit)
Configure an RMON alarm
Configure an RMON event
alarm number
MIB object to monitor
Sample interval
Test each sample directly
Test delta between samples
Configure the rising threshold
rising threshold value
Configure the falling threshold
Event to fire on rising threshold crossing
falling threshold value
Event to fire on falling threshold crossing
Specify an owner for the alarm
Alarm owner