Note:input dialer timeout here,for example 2.
Will you excute it? (Y/N):y
10.5.4 Set Wait Time of carrying interface data
Set Wait Time of carrying interface data: dialer wait-for-carrier-time seconds
Key Word:
U(undo) D(default) Q(quit)
Key Word:
U(undo) D(default) Q(quit)
......
(09)rotary-group Add this interface to a dialer rotary group
(10)string Set default telephone number
(11)wait-for-carrier-time Set the router wait for carrier time
Please Input the code of command to be excute(0-11): 11(select option wait-for-carrier-time)
Key Word:
Q(quit)
(00)<1-2147483>
Please Input the code of command to be excute(0-0): 0
Input 0,select option <1-2147483>
Please input a digital number:2
Note:input waiting time here,for example 2.
Will you excute it? (Y/N):y
10.5.5 Access Control to a DDR Interface
You can specify the packet filtering function of the DDR interface. The user can divide the packet
through the DDR interface into two kinds by access control:
Valid packet: Valid packet is the packet has passed the access control. When the DDR interface
receives a valid packet, DDR sends the packet out through the line and clears the idle timeout if the
corresponding line is connected. Otherwise, DDR sends call out.
Invalid packet: the packet hasn't passed the access control. When the DDR interface receives an
invalid packet, DDR sends the packet out through the line and doesn't clear the idle timeout if the
corresponding line is connected. Otherwise, DDR discards the packet without sending call out.
10.5.6 Set the Physical Interface Priority of dialer rotary group
The using sequense of the interfaces is determined by the priority of itself.0—the lowest, 255—the
highest, the default value is 0.
Specify the priority of the physical interface in the dialer rotary group: dialer priority number
Key Word:
U(undo) D(default) Q(quit)
Key Word:
U(undo) D(default) Q(quit)
......
(08)priority Set interface priority in dialer rotary group
(09)rotary-group Add this interface to a dialer rotary group
(10)string Set default telephone number
(11)wait-for-carrier-time Set the router wait for carrier time
Please Input the code of command to be excute(0-11): 8(select priority)
Key Word:
Q(quit)
(00)<0-255> Priority for dialing use
Please Input the code of command to be excute(0-0): 0
Please input a digital number:2(set priority,for example 2.)
Wait for carrier time in seconds