D-Link DI-1750 Reference Manual page 500

Hide thumbs Also See for DI-1750:
Table of Contents

Advertisement

(00)xxxx.xxxx.xxxx
Please Input the code of command to be excute(0-0): 0
Select 0,and input mac-address。
Step 4:
Select 28 item from listing , display:
(00)K
......
(06)partner
......
Please Input the code of command to be excute(0-16): 6
Input 6,select partner item,display:
(00)xxxx.xxxx.xxxx
Please Input the code of command to be excute(0-0): 0
Select 0,and input mac-address,display :
(00)<1-FE>
Please Input the code of command to be excute(0-0): 0
Select 0,and input sdlc-address
The default SDLC role is primary when you want to configure a SDLC multipoint link. The type of
physical units which don't has the xid in the SDLC command is PU 21, which is also a default value.
Refer to the chapter "DLSW+ configuration" for more DLSW+ configuration commands.
14.3.3 Set the SDLC as Two-way Simultaneous Mode
SDLC two-way simultaneous mode allows a primary SDLC link station to achieve more efficient use of
a full-duplex serial line. With two-way simultaneous mode, the primary link station can send data to one
secondary link station while there is a poll outstanding. Two-way simultaneous mode works on the
SDLC primary side only. On a secondary link station, it responds to a poll from the primary station.
SDLC two-way simultaneous mode operates in either a multidrop link environment or point-to-point link
environment.
In a multidrop link environment, a two-way simultaneous primary station is able to poll a secondary
station and receive data from the station, and send data (I-frames) to other secondary stations.
In a point-to-point link environment, a two-way simultaneous primary station can send data (I-frames) to
the secondary station although there is a poll outstanding, as long as the window limit is not reached.
To configure two-way simultaneous mode, use either of the following commands in interface
configuration mode:
sdlc simultaneous full-datamode
sdlc simultaneous half-datamode
Select 28 item from listing, display:
(00)K
......
(13)simultaneous
......
Please Input the code of command to be excute(0-16): 13
Input 13,select simultaneous item,display:
(00)full-datamode
(01)half-datamode
Please Input the code of command to be excute(0-1):
Select the configuration parameters
Model Name
Virtual IEEE MAC address
The size of the sending window
the remote MAC address for partner
Partners Token Ring MAC address
SDLC Address in Hex
Command
The size of the sending window
config the SDLC working in full or half-datamode
full datamode
half datamode
Enable the primary station to send data to and receive
data from the polled secondary station.
Prohibit the primary stations from sending data to the
polled secondary station.
- 498 -
Function

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di-2621Di-2630Di-3660

Table of Contents