Figure 9-1 Tsp-Link Connections; Assigning Node Numbers; Initialization - Keithley 2601 Reference Manual

System sourcemeter 2600 series (smu)
Hide thumbs Also See for 2601:
Table of Contents

Advertisement

Series 2600 System SourceMeter® Instruments Reference Manual
Figure 9-1
TSP-Link connections
Node 1
WARNING:
WARNING:
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
CHANNEL A
U L
!
C
US
S
CAT I
S
LO LO
G
HI
G
G
G
HI
LISTED
SourceMeter
4ZA4
S
G
G
G
HI
G
S
LO
HI
CAT I
!
LO
CHANNEL B
LINE FUSE
LINE RATING
!
SLOWBLOW
100-240VAC
DIGITAL I/O
3.15A, 250V
50, 60Hz
240VA MAX.
RS-232
MADE IN
U.S.A.
IEEE-488
(CHANGE IEEE ADDRESS
!
WITH FRONT PANEL MENU)
TSPlink
CAUTION:
CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
TSP-Link connectors
(2 per instrument)
RS-232
or
GPIB

Initialization

Before a TSP-Link system can be used, it must be initialized. For initialization to succeed, each
instrument in a TSP-Link system must be assigned a different node number.

Assigning node numbers

At the factory, each Series 2600 instrument is assigned as Node 1. The node number for each unit
is stored in its non-volatile memory and will not be lost when the instrument is turned off.
Front panel operation
You can use the front panel of a instrument to assign a node number to that instrument (node). You
can assign any number from 1 to 16 to the node.
Complete the following steps to assign a node number from the front panel of the instrument.
1.
Press Menu > TSPLINK > NODE.
2.
Use the navigation wheel to select the desired node number.
3.
Press in on the navigation wheel and then turn the wheel left or right to select the desired
number.
4.
Press ENTER or push in on the navigation wheel to select the node number.
Remote programming
The tsplink.node attribute is used to set the node number for an instrument:
tsplink.node = N
where : N = 1 to 16
The node number of an instrument can be determined by reading the
follows:
print(tsplink.node)
The above
value
1.000000e00
2600S-901-01 Rev. C / January 2008
Node 2
WARNING:
WARNING:
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
CHANNEL A
U L
!
C
US
S
CAT I
S
LO LO
G
HI
G
G
G
HI
LISTED
SourceMeter
4ZA4
S
G
G
G
HI
G
S
LO
S
G
G
G
HI
CAT I
!
LO
HI
CAT I
CHANNEL B
CHANNEL B
LINE FUSE
LINE RATING
!
SLOWBLOW
100-240VAC
DIGITAL I/O
DIGITAL I/O
3.15A, 250V
50, 60Hz
240VA MAX.
RS-232
MADE IN
U.S.A.
IEEE-488
IEEE-488
(CHANGE IEEE ADDRESS
!
(CHANGE IEEE ADDRESS
WITH FRONT PANEL MENU)
TSPlink
WITH FRONT PANEL MENU)
CAUTION:
CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
CAUTION:
CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
LAN crossover cables
Type: Category 5e or higher.
Length: 3 meters maximum between nodes.
Host
NOTE
The PC is not needed for
PC
stand-alone systems.
command will output the node number. For example, if the node number is 1, the
print
will be output.
Return to
Section Topics
Node 3
WARNING:
WARNING:
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
CHANNEL A
U L
!
C
US
S
CAT I
S
LO LO
G
HI
G
G
G
HI
LISTED
SourceMeter
4ZA4
HI
G
S
LO
!
LO
LINE FUSE
LINE RATING
!
SLOWBLOW
100-240VAC
3.15A, 250V
50, 60Hz
240VA MAX.
RS-232
MADE IN
U.S.A.
!
TSPlink
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
Section 9: System Expansion (TSP-Link)
Node 16
WARNING:
WARNING:
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
NO INTERNAL OPERATOR SERVICABLE PARTS,SERVICE BY QUALIFIED PERSONNEL ONLY.
CHANNEL A
U L
!
C
US
S
CAT I
S
LO LO
G
HI
G
G
G
HI
LISTED
SourceMeter
4ZA4
S
G
G
G
HI
G
S
LO
HI
CAT I
!
LO
CHANNEL B
LINE FUSE
LINE RATING
!
SLOWBLOW
100-240VAC
DIGITAL I/O
3.15A, 250V
50, 60Hz
240VA MAX.
RS-232
MADE IN
U.S.A.
IEEE-488
(CHANGE IEEE ADDRESS
!
WITH FRONT PANEL MENU)
TSPlink
CAUTION:
CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,REPLACE FUSE WITH SAME TYPE AND RATING.
tsplink.node
attribute as
9-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

26362602261126122635

Table of Contents