Command Reference - Keithley 2601 Reference Manual

System sourcemeter 2600 series (smu)
Hide thumbs Also See for 2601:
Table of Contents

Advertisement

Series 2600 System SourceMeter® Instruments Reference Manual
Table C-2
Script command equivalents
Common
command
*OPC?
*OPC
*RST
*SRE?
*SRE <mask>
*STB?
*TRG
*TST?
*WAI

Command reference

Details on all common commands except those associated with the status model are covered
below. See
*IDN? — identification query
Reads ID information
The identification string includes the manufacturer, model number, serial number, and firmware
revision levels and is sent in the following format:
Keithley Instruments Inc., Model nnnn, xxxxxxx, yyyyy
Where:
nnnn is the model number (Model 2601/2602/2611/2612/2635/2636).
xxxxxxx is the serial number.
yyyyy is the firmware revision level.
*OPC — operation complete
Sets OPC bit
*OPC? — operation complete query
Places a "1" in output queue
When *OPC is sent, the OPC bit in the Standard Event Register (see
overlapped commands complete. An ASCII "1" is also placed in the Output Queue to be read by
the *OPC? query when overlapped commands complete.
2600S-901-01 Rev. C / January 2008
Script command equivalent
waitcomplete() print([[1]])
opc()
reset()
print(tostring(status.request_enable))
status.request_enable = <mask>
print(tostring(status.condition))
N/A
print([[0]])
waitcomplete()
Appendix D
for information on using status commands.
Return to
Section Topics
Appendix C: Common Commands
Appendix
D) will set when all
C-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

26362602261126122635

Table of Contents