Staircase Sweep Functions - Keithley 2601 Reference Manual

System sourcemeter 2600 series (smu)
Hide thumbs Also See for 2601:
Table of Contents

Advertisement

Section 5: Sweep Operation

Staircase sweep functions

Functions for linear and logarithmic staircase sweeps are listed in
Table 5-2
Staircase sweep functions
Command
SweepILinMeasureV(smu, starti, stopi,
stime, points)
smu
start i
stopi
stime
points
SweepVLinMeasureI(smu, startv, stopv,
stime, points)
smu
startv
stopv
stime
points
SweepILogMeasureV(smu, starti, stopi,
stime, points)
smu
starti
stopi
stime
points
SweepVLogMeasureI(smu, startv, stopv,
stime, points)
smu
startv
stopv
stime
points
Pulse sweep functions
Functions for pulse sweeps are listed in
Table 5-3
Pulse sweep functions
Function
PulseIMeasureV(smu, bias, level, ton,
toff, points)
smu
bias
level
ton
toff
points
PulseVMeasureI(smu, bias, level, ton,
toff, points)
channel
bias
level
ton
toff
points
5-8
Series 2600 System SourceMeter® Instruments Reference Manual
Description
Define linear source current sweep:
Smu: smua for channel A or smub for channel B.
Start current value in amps.
Stop current value in amps.
Settling time (source-measure delay in seconds).
Number of points
Define linear source voltage sweep:
Smu: smua for channel A or smub for channel B.
Start voltage value in volts.
Stop voltage value in volts.
Settling time (source-measure delay in seconds).
Number of points
Define log source current sweep:
Smu: smua for channel A or smub for channel B.
Start current value in amps.
Stop current value in amps.
Settling time (source-measure delay in seconds).
Number of points
Define log source voltage sweep:
Smu: smua for channel A or smub for channel B.
Start voltage value in volts.
Stop voltage value in volts.
Settling time (source-measure delay in seconds).
Number of points
Table
5-3.
Description
Define fixed source current pulse sweep:
Smu: smua for channel A or smub for channel B.
DC bias current level in amps.
On source value of the pulse in amps.
Pulse on time in seconds.
Pulse off time in seconds.
Number of pulse-measure cycles.
Define fixed source voltage pulse sweep:
Smu: smua for channel A or smub for channel B.
DC bias voltage level in volts.
On source value of the pulse in volts.
Pulse on time in seconds.
Pulse off time in seconds.
Number of pulse-measure cycles.
Return to
Section Topics
Table
5-2.
(≥2).
(≥2).
(≥2).
(≥2).
2600S-901-01 Rev. C / January 2008

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

26362602261126122635

Table of Contents