Keithley 2601 Reference Manual page 31

System sourcemeter 2600 series (smu)
Hide thumbs Also See for 2601:
Table of Contents

Advertisement

Series 2600 System SourceMeter® Instruments Reference Manual
1 Special keys and power switch:
DISPLAY
CONFIG
POWER
Number
Keys
2 Source-measure setup, performance control, and special operation:
Top row
Models 2601, 2602, 2611, 2612, 2635, and 2636:
SRC
editing.
MEAS
LIMIT
MODE
Models 2602, 2612, and 2636 only:
SRC
MEAS
LIMIT
MODE
Middle row
Models 2601, 2602, 2611, 2612,
DIGITS
SPEED
REL
FILTER
Models 2602, 2612, and 2636 only:
DIGITS
SPEED
REL
FILTER
Bottom row
LOAD
RUN
STORE
RECALL
2600S-901-01 Rev. C / January 2008
Toggles between the various source-measure displays and the user message mode.
Selects Model 2602/2612/2636 single or dual-channel display.
Use to configure a function or operation.
Power switch: The in position turns SourceMeter on (I); the out position turns it off (O).
The number keys (0-9, +/-, 0000) allow direct numeric entry in the EDIT mode.
Channel A selects the source function (V or A) and places cursor in the source field for
Channel A cycles through measure functions (V, A, Ω, or W).
Channel A places the cursor in the compliance limit field for editing.
Channel A directly chooses the measurement function (V, A, Ω, or W).
Channel B selects the source function (V or A) and places cursor in the source field.
Channel B cycles through measure functions (V, A, Ω, or W).
Channel B places the cursor in the compliance limit field for editing.
Channel B directly chooses the measurement function (V, A, Ω, or W).
2635, and 2636
Channel A changes display resolution to 4-1/2, 5-1/2, or 6-1/2 digits.
Channel A sets the measurement speed by controlling the A/D converter measurement
aperture.
Channel A controls relative, which allows a baseline value to be subtracted from a reading.
Channel A controls the digital filter, which can be used to reduce reading noise.
Channel B changes display resolution to 4-1/2, 5-1/2, or 6-1/2 digits.
Channel B sets the measurement speed by controlling the A/D converter measurement
aperture.
Channel B controls relative, which allows a baseline value to be subtracted from a reading.
Channel B controls the digital filter, which can be used to reduce reading noise.
Loads factory or user-defined scripts for execution.
Runs the last selected factory or user-defined scripts.
Stores readings, source values, and timestamp values in one of two internal buffers
per channel for later recall.