SATO CL4NX Operator's Manual page 239

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

High (with I-mark) - Low ≥ 1.0 (V)
[I-Mark Slice Level]
Set the I-mark sensor slice level.
The setting procedure is as follows:
1. Use the following formula to calculate the slice level:
(High level - Low level) x 0.7 + Low level = slice level
2. Select the [I-Mark Slice Level] in the [Calibrate] menu and press the
3. Press the
calculated in step 1.
4. Press the
If you set the [Slice level] to 0.0 (V), the printer sets the slice level automatically.
[Head Check]
/
buttons to change the [Slice level] value. Set the [Slice level] to the slice level
button to confirm the value.
239
button.