[GAP Levels]
Manually set the Gap sensor level.
The setting procedure is as follows:
First, adjust the "Low" level (voltage) of the Gap sensor.
1. Remove the label from the liner.
2. Pass the liner through the media sensor. Align it so that the media sensor does not detect the I-
mark (black mark).
3. Close the print head. To get the correct adjustment result, adjust after you have closed the print
head.
4. Select the [GAP Levels] in the [Calibrate] menu and press the
5. Press the
Set the [Emit] value as low as possible.
6. If the [Sensor] value does not decrease below 0.5 after you changed the [Emit] value, press the
/
buttons to change the [Receive] value.
7. Take a note of the [Sensor] value from the above procedure. This is the "Low" level value for the
Gap sensor.
Next, check the "High" level (voltage) of the Gap sensor as follows:
1. Pass the media (attached with liner) between the media sensors. Align it so that the media sensor
does not detect the I-mark (black mark).
2. Close the print head.
3. Check the [Sensor] value.
If the value is 1.0 (V) higher than the "Low" level value you have recorded, this is the "High" level
value for the Gap sensor.
If the difference between the "High" and the "Low" levels is less than 1.0, adjust the [Emit] and
[Receive] values so that the difference is more than 1.0, or adjust the "Low" level (voltage) of the
Gap sensor again.
4. If both "High" and "Low" levels comply with the standard value, press the
confirm the value.
The standard values for the "High" and "Low" levels for the Gap sensor are as follows:
/
buttons to change the [Emit] value until the [Sensor] value is below 0.5 (V).
236
[Advanced]
button.
button to