◦
Low (with only liner) ≤ 0.5 (V)
◦
High (media attached with liner) - Low ≥ 1.0 (V)
[GAP Slice Level]
Set the Gap sensor slice level.
The setting procedure is as follows:
1. Use the following formula to calculate the slice level:
(High level - Low level) x 0.3 + Low level = slice level
2. Select the [GAP Slice Level] in the [Calibrate] menu and press the
3. Press the
calculated in step 1.
4. Press the
•
If you set the [Slice level] to 0.0 (V), the printer sets the slice level automatically.
/
buttons to change the [Slice level] value. Set the [Slice level] to the level
button to confirm the value.
237
button.