Configure alarms
Other fields
In addition to the required fields described above, the header section of an email can also contain
one or more optional fields. Many such fields are defined in the relevant RFCs, but there are some
fields the router handles a little differently, as described below. The router inserts other fields as
necessary if it is required to send attachments with the email.
Reply To
If the router discovers this field is not present in the email template, it inserts this field into the
header. The string for this field is the one configured by the smtp 0 reply_to CLI command (or
the use Reply To address parameter in the Configuration > Alarms > SMTP Account web page).
This allows for different reply addresses, and a simple way of using the same (easily
configurable) reply address for all emails.
Date
If this field is present in the header, the router inserts the current date and time into the header.
The date and time are values local to the router and do not contain any time zone information.
Body section
The body section can include any text. This text is parsed for any function calls that may be present.
Function calls must be enclosed between <% and %>. These sequences are substituted by text
resulting from the function call. You can use the following functions:
Function
TimeSmtp();
serial_number();
Smtpip();
email_event()
Smtpid()
pppip("instance");
Digi TransPort WR Routers User Guide
Description
Inserts the router's date and time.
Inserts the router's serial number
Inserts the IP address of the router as seen by the SMTP server during transmission
Inserts a formatted description of the event that caused the email transmission.
Inserts the router ID for this device as configured by the Router Identity field in the
Configuration > System > Device Identity web page, or the cmd 0 unitid CLI
command.
Inserts the IP address for a specific PPP instance, where instance is the PPP instance
number.
Event Settings parameters