Use the command-line interface
S16 RS422/485 serial port settings
The RS485 option is only available on specific hardware versions.
Units: N/A
Default: 0
Range: 0, 2, 3, where 0=RS232, 2=RS485 full duplex, 3=RS485 half duplex
Following example shows how to setup and save ASY 0 in 485 half-duplex mode
AT\port=0
ATS16=3
AT&w
AT\port
The at\port=0 is needed to ensure that subsequent AT commands are directed to the right port
(ASY0). The port settings can be saved permanently using AT&W.
Issue the command ats16? and check that the value of this S register is 3. To set it back to RS232
then set ATS16 to 0 and save it with the &w command.
S23 Parity
Units: N/A
Default: 0
Range: 0-2,5,6
The value stored in S23 determines whether the parity for the ASY port is set to None (0), Odd (1),
Even (2), 8Data Odd (5) or 8Data Even (6).