Digi TransPort WR31 User Manual page 269

Hide thumbs Also See for TransPort WR31:
Table of Contents

Advertisement

Configure network interfaces
Stop data from being transmitted after n units
The total amount of data that may be transmitted by this PPP instance before the link is blocked
for further traffic. The value in the drop-down list specifies the units: KBytes, MBytes, or GBytes.
Reset the data limit on the n day of the month
The day of the month on which the data limit is reset to 0.
Related CLI commands
Entity
Instance
Parameter
ppp
n
metric
ppp
n
aodion
ppp
n
immoos
ppp
n
aodi_dly
ppp
n
aodi_dly2
ppp
n
pwr_dly
ppp
n
tband
ppp
n
minup
ppp
n
maxup
ppp
n
maxuptime
ppp
n
timeout
ppp
n
timeout2
ppp
n
rxtimeout
ppp
n
maxneg
ppp
n
uplogmins
ppp
n
dlwarnkb
Digi TransPort WR Routers User Guide
Values
0-255
0-2
0=disabled
1=enabled
2=On and return to
service immediately
on, off
0-2147483647
0-2147483647
0-2147483647
0-4
0-2147483647
0-2147483648
0-2147483647
0-2147483648
0-2147483648
0-2147483648
0-2147483648
0-2147483647
0-2147483647
Configure DialServ interfaces
Equivalent web parameter
Metric
Enable "Always On" mode of this interface,
On, On and return to service immediately
Put this interface "Out of Service" when an
always-on connection attempt fails
Attempt to reconnect after s seconds
If an inhibited PPP interface is connected,
attempt to re-connect after s seconds
Wait s seconds after power-up before
activating this interface
Control when this interface can connect using
Time Band n
Keep this interface up for at least s seconds
Close this interface after s seconds
if it has been up for m minutes in a day
if the link has been idle for s seconds
Alternative idle timer for static routes s
seconds
if the link has not received any packets for s
seconds
if the negotiation is not complete in s seconds
Generate an event after this interface has
been up for m mins
Issue a warning after n units
269

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents