Configure legacy protocols
CALL command: Make an X.25 call
The full structure of a CALL command is:
CALL [<facilities->]<address>[D<user data>]
where:
<facilities-> is an optional list of codes indicating the facilities to be requested in the call
(separated by commas, terminated with a dash)
<address> is the destination network address.
<user data> is any optional user data to be included with the call.
The facility codes supported are:
F: Fast select-no restriction
Q: Fast select-restricted response
Gnn: Closed User Group
Gnnnn: Extended Closed User Group
R: Reverse charging
N<NUI>: Network User Identity code (NUI)
Example
The following command places a call to address 56512120 using reverse charging and specifying
Closed User Group 12. The string MYNUI is your Network User Identity. The string Hello appears in
the user data field of the call packet.
CALL R,G12,NMYNUI-56512120DHello
Note
The particular facilities available vary among X.25 service providers.
If a CALL command is issued without the address parameter, it is assumed you want to go back on-
line to a previously established call, using the PAD recall facility to temporarily return to the PAD>
prompt.
Digi TransPort WR Routers User Guide