Quantum Data 881 User Manual page 76

Hide thumbs Also See for 881:
Table of Contents

Advertisement

64
Chapter 2 Testing Video Displays
5. Choose Images, and then select the image you want to use.
The image appears and begins shifting in accordance with default settings for both
speed and method of shifting (either repeat or reversed). The following settings appear
on the 882's display as shown below.
>Line
HInc:
1
VInc:
1
*TInc:
1
a. Configure image shifting parameters by selecting a parameter using its adjacent
soft key, then adjusting the value by pressing the + or - keys.
Refer to the following table for a description of the parameters used to control image
shifting.
Parameter
Line
HInc
VInc
TInc
6. To set the starting point of the image shift, press the Settings key. The following
settings appear on the 882's display.
Path
Start Point
X
Y
000
000
You can set the starting coordinates of the image shift as follows:
a. To specify the X Start Point, position the blinking cursor on the digits of the X
coordinate you wish to change. To do this, press the soft key adjacent to the arrow
Reversed<
Exit!
Action
Selects image shifting pattern. This can
be either Reverse or Repeat.
• Reverse moves the image in both
directions in accordance with the
shift parameters.
• Repeat moves the image in only one
direction.
Specifies number of pixels the image
travels in a horizontal direction per time
period.
Specifies number of lines the image
travels in a vertical direction per time
period.
Specifies movement to occur per N
number of frames.
->
->