Quantum Data 881 User Manual page 856

Hide thumbs Also See for 881:
Table of Contents

Advertisement

PDAX:ERRQ
Class
Description
Query syntax
Query response
Example
478
Appendix A Command Reference
Pixel Data Analyzer ERRor Query
Signal analyzer - Pixel data
Retrieves one or more of the recorded detailed error records. The count is persistent in
that the last entered count will be used in subsequent queries if a count value is not
specified. If the start is not specified then the query will start where the previous query left
off.
PDAX:ERRQ? start count
start
The starting index of the error count. Default is 1.
count
The maximum number of errors to report. The initial count is 10.
frame, x y mr mg mb rr rg rb
frame
The number of the frame that the error occurred in.
x, y
The coordinate that the error occurred on.
mr
The measured red component value.
mg
The measured red component value.
mb
The rmeasured red component value.
rr
The reference expected red component value.
rg
The reference expected green component value.
rb
The reference expected blue component value.
PDAX:FRMS 100 //sets the number of frames to analyze in the pixel
data analysis test to 100
PDAX:MXER 1000 //sets the maximum number of errors to record in pixel
data analysis test to 1000