FSPW
Class
Description
Command syntax
Query syntax
Query response
Other required
commands
Example
356
Appendix A Command Reference
Frame Sync Pulse Width
Format parameter setting - Synchronization
Establishes the width of the frame sync pulse. The FSPW? query returns the current
setting of FSPW.
FSPW pixels
pixels
min = 1
max = HTOT - 1
FSPW?
pixels
The
FMTU
command instructs the generator to use the new settings. The
updates the hardware to the new settings and redraws the test image.
FSPG 1
// Enable Frame Sync
FSPP 1
// Set for positive going pulse
FSPW 20
// Make the pulse 20 pixels wide
FSPG 300
// Pulse to occur 300 lines after the last line of active video
FMTU
// Update hardware to new settings
ALLU
command