Quantum Data 881 User Manual page 502

Hide thumbs Also See for 881:
Table of Contents

Advertisement

124
Chapter 14 Using Special Sync Output
3. Set the frame pulse polarity (either 0 for low or 1 for high) by entering the following
command:
FSPP
1
4. Set the frame pulse pixel width by entering the following command:
FSPW
100
// range: 1 pixel to
5. Set the frame pulse delay by entering the following command:
FSPD
10
// range: 0 <=
6. Save these settings by entering the following command:
ALLU
To configure line sync on the special sync output:
1. Enable the line sync signal by entering the following commands:
FSPG
0
PSPG
0
LSPG
1
ALLU
The value of composite sync (CSPG) does not matter once these are set.
2. Set the line sync pulse polarity by entering the following command:
LSPP
1
// 1 = high (default)
ALLU
To configure composite sync on the special sync output:
1. Enable digital composite sync by entering the following command:
SSST
2
//(or 6,11)
2. Enable the composite sync signal by entering the following commands:
FSPG
0
PSPG
0
LSPG
0
CSPG
1
ALLU
3. Set the composite sync pulse polarity by entering the following commands:
CSPP
1
// 1 = high (default)
ALLU
HTOT
- 1
FSPD
<
(VTOT
-
FSPW
- 1); default = 0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

882